Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,289
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0206 # 02 Y:2001 | 02 | 2001 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,202 | $2,000 | Not Implemented |
NC0206 # 03 Y:2001 | 03 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $589 | $270 | Implemented |
NC0206 # 04 Y:2001 | 04 | 2001 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $204 | $525 | Implemented |
NC0206 # 05 Y:2001 | 05 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,083 | $32,849 | Not Implemented |
NC0206 # 06 Y:2001 | 06 | 2001 | INSULATE BARE EQUIPMENT | $307 | $65 | Not Implemented |
NC0206 # 07 Y:2001 | 07 | 2001 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,568 | $0 | Not Implemented |
NC0206 # 08 Y:2001 | 08 | 2001 | REDESIGN PROCESS | $9,810 | $40,000 | Implemented |
NC0206 # 09 Y:2001 | 09 | 2001 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $1,200 | $2,500 | Not Implemented |
NC0206 # 10 Y:2001 | 10 | 2001 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $3,210 | $6,000 | Not Implemented |
NC0207 # 01 Y:2001 | 01 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $423 | $2,700 | Not Implemented |
NC0207 # 02 Y:2001 | 02 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,148 | $750 | Implemented |
NC0207 # 03 Y:2001 | 03 | 2001 | TURN OFF EQUIPMENT WHEN NOT IN USE | $16,705 | $10,000 | Implemented |
NC0207 # 04 Y:2001 | 04 | 2001 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $15,272 | $12,600 | Implemented |
NC0207 # 05 Y:2001 | 05 | 2001 | AIR CONDITION ONLY SPACE NECESSARY | $13,400 | $12,400 | Implemented |
OD0172 # 01 Y:2000 | 01 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $89,664 | $154,663 | Implemented |
OD0172 # 02 Y:2000 | 02 | 2000 | REPAIR OR REPLACE STEAM TRAPS | $19,058 | $2,100 | Not Implemented |
OD0172 # 03 Y:2000 | 03 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,087 | $1,800 | Implemented |
NC0202 # 01 Y:2000 | 01 | 2000 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,541 | $7,971 | Implemented |
NC0202 # 02 Y:2000 | 02 | 2000 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $9,464 | $865 | Implemented |
NC0202 # 03 Y:2000 | 03 | 2000 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $4,647 | $0 | Implemented |
NC0202 # 04 Y:2000 | 04 | 2000 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $108 | $200 | Not Implemented |
NC0202 # 05 Y:2000 | 05 | 2000 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $18,762 | $3,000 | Not Implemented |
NC0202 # 06 Y:2000 | 06 | 2000 | RECOVER AND REUSE COOLING WATER | $2,950 | $2,000 | Implemented |
NC0204 # 01 Y:2000 | 01 | 2000 | ADJUST BURNERS FOR EFFICIENT OPERATION | $4,201 | $2,350 | Implemented |
NC0204 # 02 Y:2000 | 02 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,133 | $257 | Implemented |