IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

4,184

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
ND0346 # 11 Y:2000 11 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,834 $7,999 Not Implemented
ND0346 # 12 Y:2000 12 2000 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,827 $320 Implemented
ND0346 # 13 Y:2000 13 2000 INSTALL OCCUPANCY SENSORS $330 $400 Not Implemented
ND0346 # 14 Y:2000 14 2000 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $64 $10 Implemented
UM0161 # 01 Y:2000 01 2000 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,365 $450 Implemented
UM0161 # 02 Y:2000 02 2000 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,614 $500 Not Implemented
UM0161 # 03 Y:2000 03 2000 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $48,437 $500 Implemented
UM0161 # 04 Y:2000 04 2000 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $1,098 $656 Not Implemented
UM0161 # 05 Y:2000 05 2000 UPGRADE OBSOLETE EQUIPMENT $5,016 $5,700 Not Implemented
UM0160 # 01 Y:2000 01 2000 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,149 $200 Implemented
UM0160 # 02 Y:2000 02 2000 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $582 $50 Implemented
UM0160 # 03 Y:2000 03 2000 USE POWER DURING OFF-PEAK PERIODS $55,632 $22,000 Implemented
UM0160 # 04 Y:2000 04 2000 AIR CONDITION ONLY SPACE NECESSARY $2,800 $220 Implemented
UM0160 # 05 Y:2000 05 2000 RECOVER AND REUSE WASTE MATERIAL $7,300 $500 Implemented
UM0160 # 06 Y:2000 06 2000 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $1,600 $300 Not Implemented
UM0159 # 01 Y:2000 01 2000 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $1,800 $200 Implemented
UM0159 # 02 Y:2000 02 2000 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $172 $50 Implemented
UM0159 # 03 Y:2000 03 2000 ADJUST BURNERS FOR EFFICIENT OPERATION $10,836 $3,000 Implemented
UM0159 # 04 Y:2000 04 2000 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $4,390 $4,000 Implemented
UM0159 # 05 Y:2000 05 2000 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $4,800 $8,000 Implemented
UM0159 # 06 Y:2000 06 2000 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $88,447 $27,000 Implemented
UM0159 # 07 Y:2000 07 2000 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $95,726 $35,000 Not Implemented
UM0158 # 01 Y:2000 01 2000 REPAIR OR REPLACE STEAM TRAPS $67,296 $2,200 Implemented
UM0158 # 02 Y:2000 02 2000 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $6,190 $1,400 Not Implemented
UM0158 # 03 Y:2000 03 2000 INCREASE AMOUNT OF CONDENSATE RETURNED $138,702 $86,970 Implemented