Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,184
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0151 # 04 Y:1999 | 04 | 1999 | USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS | $5,903 | $11,000 | Implemented |
UM0151 # 05 Y:1999 | 05 | 1999 | USE FIXTURES TO REDUCE MACHINE CHANGEOUT TIMES | $13,689 | $960 | Not Implemented |
UM0148 # 01 Y:1999 | 01 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,826 | $2,464 | Implemented |
UM0148 # 02 Y:1999 | 02 | 1999 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,069 | $500 | Not Implemented |
UM0148 # 03 Y:1999 | 03 | 1999 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $10,056 | $40,000 | Not Implemented |
UM0148 # 04 Y:1999 | 04 | 1999 | RECOVERY METALS FROM RINSE WATER(EVAP., ION EXCHANGE, RO, ELECTROLYSIS, ELECTRODIALYSIS) AND REUSE RINSE WATER | $12,311 | $40,000 | Implemented |
UM0148 # 05 Y:1999 | 05 | 1999 | EXPAND OPERATIONS INTO UNUSED SPACE | $342,900 | $683,000 | Not Implemented |
UM0146 # 01 Y:1999 | 01 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,736 | $220 | Not Implemented |
UM0146 # 02 Y:1999 | 02 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $78 | $200 | Not Implemented |
UM0146 # 03 Y:1999 | 03 | 1999 | INSULATE BARE EQUIPMENT | $2,510 | $200 | Not Implemented |
UM0146 # 04 Y:1999 | 04 | 1999 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $15,807 | $40,000 | Not Implemented |
UM0146 # 05 Y:1999 | 05 | 1999 | USE A RAG RECYCLE SERVICE | $925 | $0 | Not Implemented |
UM0146 # 06 Y:1999 | 06 | 1999 | IMPROVE SPACE COMFORT CONDITIONING | $6,000 | $3,600 | Not Implemented |
UM0146 # 07 Y:1999 | 07 | 1999 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $11,207 | $40,000 | Not Implemented |
UM0145 # 01 Y:1999 | 01 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,720 | $300 | Implemented |
UM0145 # 02 Y:1999 | 02 | 1999 | USE RADIANT HEATER FOR SPOT HEATING | $2,157 | $4,500 | Not Implemented |
UM0145 # 03 Y:1999 | 03 | 1999 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $14,970 | $40,000 | Not Implemented |
UM0145 # 04 Y:1999 | 04 | 1999 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $8,978 | $11,600 | Not Implemented |
UM0145 # 05 Y:1999 | 05 | 1999 | USE REVERSE OSMOSIS TO CONCENTRATE MATERIAL | $50,143 | $85,000 | Not Implemented |
UM0145 # 06 Y:1999 | 06 | 1999 | USE ABSORPTION, EXTRACTION TO REMOVE CONTAMINANTS | $24,222 | $60,000 | Implemented |
UM0145 # 07 Y:1999 | 07 | 1999 | IMPROVE SPACE COMFORT CONDITIONING | $16,869 | $14,495 | Implemented |
UM0145 # 08 Y:1999 | 08 | 1999 | INSTALL MAGAZINES FOR TEMPORARY STORAGE | $32,500 | $2,000 | Not Implemented |
UM0144 # 01 Y:1999 | 01 | 1999 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,661 | $110 | Implemented |
UM0144 # 02 Y:1999 | 02 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $647 | $1,000 | Implemented |
UM0144 # 03 Y:1999 | 03 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,285 | $350 | Implemented |