Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,597
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UK1614 # 06 Y:2017 | 06 | 2017 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $895 | $0 | Not Implemented |
UK1614 # 07 Y:2017 | 07 | 2017 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $552 | $318 | Not Implemented |
UK1614 # 08 Y:2017 | 08 | 2017 | USE ONLY CERTIFIED MOTOR REPAIR SHOPS | $1,614 | $4,335 | Implemented |
UK1614 # 09 Y:2017 | 09 | 2017 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $823 | $0 | Not Implemented |
NC0588 # 01 Y:2017 | 01 | 2017 | INSULATE BARE EQUIPMENT | $24,750 | $80,000 | Not Implemented |
NC0588 # 02 Y:2017 | 02 | 2017 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $4,845 | $38,000 | Not Implemented |
NC0588 # 03 Y:2017 | 03 | 2017 | USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR | $26,851 | $133,000 | Not Implemented |
NC0588 # 04 Y:2017 | 04 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $23,766 | $97,500 | Implemented |
NC0588 # 05 Y:2017 | 05 | 2017 | DEVELOP A REPAIR/REPLACE POLICY | $2,286 | $5,865 | Implemented |
NC0590 # 01 Y:2017 | 01 | 2017 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $37,015 | $250 | Not Implemented |
NC0590 # 02 Y:2017 | 02 | 2017 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $3,356 | $0 | Implemented |
NC0590 # 03 Y:2017 | 03 | 2017 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $3,139 | $4,200 | Not Implemented |
NC0590 # 04 Y:2017 | 04 | 2017 | RECOVER WASTE HEAT FROM EQUIPMENT | $15,073 | $6,000 | Not Implemented |
NC0590 # 05 Y:2017 | 05 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,529 | $9,666 | Implemented |
NC0590 # 06 Y:2017 | 06 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,501 | $6,171 | Implemented |
NC0590 # 07 Y:2017 | 07 | 2017 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $45 | $100 | Implemented |
NC0590 # 08 Y:2017 | 08 | 2017 | TURN OFF STEAM / HOT WATER LINES LEADING TO SPACE HEATING UNITS | $48 | $65 | Implemented |
NC0590 # 09 Y:2017 | 09 | 2017 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,273 | $230 | Implemented |
NC0590 # 10 Y:2017 | 10 | 2017 | DEVELOP A REPAIR/REPLACE POLICY | $1,448 | $5,865 | Implemented |
NL0001 # 01 Y:2017 | 01 | 2017 | UPGRADE OBSOLETE EQUIPMENT | $28,978 | $82,175 | Not Implemented |
NL0001 # 02 Y:2017 | 02 | 2017 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $400 | $0 | Not Implemented |
NL0001 # 03 Y:2017 | 03 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $850 | $1,000 | Implemented |
NL0001 # 04 Y:2017 | 04 | 2017 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $3,808 | $0 | Not Implemented |
NL0001 # 05 Y:2017 | 05 | 2017 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,694 | $17,700 | Not Implemented |
NL0001 # 06 Y:2017 | 06 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $19,200 | $78,000 | Implemented |