Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,302
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0775 # 09 Y:2008 | 09 | 2008 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $82 | $0 | Implemented |
UW0010 # 01 Y:2008 | 01 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $14,108 | $4,160 | Implemented |
UW0010 # 02 Y:2008 | 02 | 2008 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $7,398 | $75,533 | Not Implemented |
UW0010 # 03 Y:2008 | 03 | 2008 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $5,340 | $3,000 | Not Implemented |
SF0353 # 01 Y:2008 | 01 | 2008 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $9,294 | $2,185 | Not Implemented |
SF0353 # 02 Y:2008 | 02 | 2008 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,063 | $1,355 | Not Implemented |
SF0353 # 03 Y:2008 | 03 | 2008 | INSTALL OCCUPANCY SENSORS | $2,458 | $2,016 | Implemented |
SF0353 # 04 Y:2008 | 04 | 2008 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $45,262 | $60,000 | Not Implemented |
SF0353 # 05 Y:2008 | 05 | 2008 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,324 | $2,426 | Not Implemented |
SF0353 # 06 Y:2008 | 06 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $9,259 | $18,610 | Not Implemented |
SF0353 # 07 Y:2008 | 07 | 2008 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $853 | $1,675 | Not Implemented |
SF0353 # 08 Y:2008 | 08 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $89,877 | $118,644 | Implemented |
SF0353 # 09 Y:2008 | 09 | 2008 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $4,960 | $24,943 | Implemented |
SF0353 # 10 Y:2008 | 10 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,273 | $11,479 | Not Implemented |
SF0353 # 11 Y:2008 | 11 | 2008 | INSULATE BARE EQUIPMENT | $2,256 | $22,235 | Implemented |
UA0014 # 01 Y:2008 | 01 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,796 | $0 | Implemented |
UA0014 # 02 Y:2008 | 02 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,143 | $1,040 | Implemented |
UA0014 # 03 Y:2008 | 03 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,493 | $2,877 | Not Implemented |
UA0014 # 04 Y:2008 | 04 | 2008 | OPTIMIZE PLANT POWER FACTOR | $5,800 | $14,850 | Not Implemented |
UA0014 # 05 Y:2008 | 05 | 2008 | INSTALL TIMERS AND/OR THERMOSTATS | $1,454 | $591 | Implemented |
UA0014 # 06 Y:2008 | 06 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,934 | $13,520 | Not Implemented |
UA0014 # 07 Y:2008 | 07 | 2008 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $457 | $72 | Implemented |
UA0014 # 08 Y:2008 | 08 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,943 | $1,164 | Not Implemented |
UA0014 # 09 Y:2008 | 09 | 2008 | INSTALL OCCUPANCY SENSORS | $2,288 | $770 | Not Implemented |
UA0014 # 10 Y:2008 | 10 | 2008 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $644 | $700 | Not Implemented |