Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
396
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
DS0112 # 02 Y:1998 | 02 | 1998 | USE POWER DURING OFF-PEAK PERIODS | $3,019 | $1,375 | Implemented |
DS0112 # 03 Y:1998 | 03 | 1998 | RECOVER WASTE HEAT FROM EQUIPMENT | $12,228 | $12,710 | Not Implemented |
DS0112 # 04 Y:1998 | 04 | 1998 | RECOVER WASTE HEAT FROM EQUIPMENT | $775 | $680 | Not Implemented |
DS0112 # 05 Y:1998 | 05 | 1998 | IMPROVE HANDLING PRACTICES | $360 | $352 | Not Implemented |
DS0112 # 06 Y:1998 | 06 | 1998 | ESTABLISH EQUIPMENT MAINTENANCE SCHEDULE | $259 | $0 | Implemented |
DS0078 # 01 Y:1997 | 01 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,806 | $28,425 | Implemented |
DS0078 # 02 Y:1997 | 02 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,342 | $750 | Implemented |
DS0078 # 03 Y:1997 | 03 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,866 | $17,925 | Not Implemented |
DS0078 # 04 Y:1997 | 04 | 1997 | INSULATE BARE EQUIPMENT | $14,716 | $19,230 | Not Implemented |
DS0078 # 05 Y:1997 | 05 | 1997 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $1,360 | $100 | Not Implemented |
DS0078 # 06 Y:1997 | 06 | 1997 | INCREASE USE OF AUTOMATION | $752,148 | $810,000 | Not Implemented |
DS0078 # 07 Y:1997 | 07 | 1997 | RECOVER AND REUSE WASTE MATERIAL | $36,169 | $0 | Not Implemented |
DS0075 # 01 Y:1996 | 01 | 1996 | OPTIMIZE PLANT POWER FACTOR | $2,348 | $1,700 | Implemented |
DS0075 # 02 Y:1996 | 02 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,487 | $21,753 | Implemented |
DS0075 # 03 Y:1996 | 03 | 1996 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $8,576 | $8,500 | Implemented |
DS0075 # 04 Y:1996 | 04 | 1996 | USE A DIFFERENT OR RECYCLED RAW MATERIAL | $21,114 | $0 | Not Implemented |
DS0075 # 05 Y:1996 | 05 | 1996 | INSTALL SET-BACK TIMERS | $2,926 | $150 | Implemented |
DS0075 # 06 Y:1996 | 06 | 1996 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,520 | $0 | Implemented |
DS0069 # 01 Y:1996 | 01 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,691 | $4,761 | Implemented |
DS0069 # 02 Y:1996 | 02 | 1996 | TURN OFF EQUIPMENT WHEN NOT IN USE | $969 | $0 | Implemented |
DS0069 # 03 Y:1996 | 03 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $206 | $3,216 | Not Implemented |
DS0069 # 04 Y:1996 | 04 | 1996 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $6,240 | $100 | Implemented |
DS0069 # 05 Y:1996 | 05 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,323 | $600 | Implemented |
DS0069 # 06 Y:1996 | 06 | 1996 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $8,400 | $6,720 | Not Implemented |
DS0042 # 01 Y:1995 | 01 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,705 | $6,010 | Implemented |