Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,204
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SU0244 # 11 Y:2006 | 11 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $448 | $356 | Implemented |
SU0244 # 12 Y:2006 | 12 | 2006 | OPTIMIZE PLANT POWER FACTOR | $11,590 | $30,856 | Not Implemented |
SU0244 # 13 Y:2006 | 13 | 2006 | INSTALL EQUIPMENT TO UTILIZE WASTE FUEL | $1,187,734 | $4,100,000 | Not Implemented |
TA0125 # 01 Y:2006 | 01 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,191 | $155 | Implemented |
TA0125 # 02 Y:2006 | 02 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $894 | $0 | Implemented |
TA0125 # 03 Y:2006 | 03 | 2006 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $268,990 | $0 | Implemented |
TA0125 # 04 Y:2006 | 04 | 2006 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $421 | $0 | Implemented |
UM0315 # 01 Y:2006 | 01 | 2006 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $53,281 | $1,800 | Not Implemented |
UM0315 # 02 Y:2006 | 02 | 2006 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $36,263 | $15,000 | Not Implemented |
UM0315 # 03 Y:2006 | 03 | 2006 | RECOVER WASTE HEAT FROM EQUIPMENT | $34,667 | $8,066 | Not Implemented |
UM0315 # 04 Y:2006 | 04 | 2006 | INSULATE BARE EQUIPMENT | $32,300 | $80,207 | Not Implemented |
UM0315 # 05 Y:2006 | 05 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $27,713 | $40,991 | Not Implemented |
UM0315 # 06 Y:2006 | 06 | 2006 | INSULATE BARE EQUIPMENT | $1,369 | $230 | Not Implemented |
UM0315 # 07 Y:2006 | 07 | 2006 | ADD AREA LIGHTING SWITCHES | $1,294 | $1,100 | Not Implemented |
UM0315 # 08 Y:2006 | 08 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $526 | $225 | Implemented |
UU0112 # 01 Y:2006 | 01 | 2006 | TURN OFF EQUIPMENT WHEN NOT IN USE | $0 | $0 | Not Implemented |
UU0112 # 02 Y:2006 | 02 | 2006 | REPAIR OR REPLACE STEAM TRAPS | $121,540 | $8,720 | Not Implemented |
UU0112 # 03 Y:2006 | 03 | 2006 | CLOSE OFF UNNEEDED STEAM LINES | $140,530 | $250,000 | Not Implemented |
UU0112 # 04 Y:2006 | 04 | 2006 | INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) | $69,680 | $200,000 | Not Implemented |
UU0112 # 05 Y:2006 | 05 | 2006 | TURN OFF STEAM / HOT WATER LINES LEADING TO SPACE HEATING UNITS | $65,810 | $442,960 | Not Implemented |
UU0112 # 06 Y:2006 | 06 | 2006 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,030 | $0 | Not Implemented |
UM0314 # 01 Y:2006 | 01 | 2006 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $62,424 | $69,750 | Not Implemented |
UM0314 # 02 Y:2006 | 02 | 2006 | STORE HEATED/ COOLED WATER FOR USE DURING PEAK DEMAND PERIODS | $30,865 | $25,000 | Not Implemented |
UM0314 # 03 Y:2006 | 03 | 2006 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $12,963 | $2,480 | Implemented |
UM0314 # 04 Y:2006 | 04 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $12,296 | $7,000 | Not Implemented |