Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,520
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MS0136 # 02 Y:1999 | 02 | 1999 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $561 | $334 | Not Implemented |
MS0136 # 03 Y:1999 | 03 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,618 | $1,130 | Not Implemented |
MS0136 # 04 Y:1999 | 04 | 1999 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,296 | $3,418 | Not Implemented |
MS0136 # 05 Y:1999 | 05 | 1999 | INSTALL SET-BACK TIMERS | $717 | $472 | Not Implemented |
MS0136 # 06 Y:1999 | 06 | 1999 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS | $279,396 | $26,310 | Not Implemented |
WI0351 # 01 Y:1999 | 01 | 1999 | INSTALL SHELVES / RACKS TO UTILIZE UNUSED SPACE | $19,500 | $18,000 | Not Implemented |
WI0351 # 02 Y:1999 | 02 | 1999 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $7,993 | $0 | Implemented |
WI0351 # 03 Y:1999 | 03 | 1999 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $7,922 | $500 | Not Implemented |
WI0351 # 04 Y:1999 | 04 | 1999 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $5,378 | $0 | Implemented |
WI0351 # 05 Y:1999 | 05 | 1999 | INSTALL TIMERS AND/OR THERMOSTATS | $4,145 | $800 | Not Implemented |
WI0351 # 06 Y:1999 | 06 | 1999 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $4,075 | $0 | Not Implemented |
WI0351 # 07 Y:1999 | 07 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,173 | $1,920 | Implemented |
WI0351 # 08 Y:1999 | 08 | 1999 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $1,365 | $4,374 | Implemented |
WI0351 # 09 Y:1999 | 09 | 1999 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $843 | $800 | Implemented |
TN0662 # 01 Y:1999 | 01 | 1999 | INITIATE A PROGRAM TO ACQUIRE ISO CERTIFICATION | $55,900 | $90,000 | Not Implemented |
TN0662 # 02 Y:1999 | 02 | 1999 | MODIFY CURRENT INCENTIVE PROGRAM | $45,000 | $30,000 | Implemented |
TN0662 # 03 Y:1999 | 03 | 1999 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $16,380 | $4,260 | Not Implemented |
TN0662 # 04 Y:1999 | 04 | 1999 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $14,050 | $19,800 | Implemented |
TN0662 # 05 Y:1999 | 05 | 1999 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,010 | $1,460 | Implemented |
TN0662 # 06 Y:1999 | 06 | 1999 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $970 | $2,225 | Not Implemented |
OK0570 # 01 Y:1999 | 01 | 1999 | INSTALL OCCUPANCY SENSORS | $726 | $2,286 | n/a |
OK0570 # 02 Y:1999 | 02 | 1999 | PAY BILLS ON TIME TO AVOID LATE FEES | $333 | $0 | n/a |
OK0570 # 03 Y:1999 | 03 | 1999 | IMPROVE SPACE COMFORT CONDITIONING | $40,159 | $2,880 | n/a |
OK0570 # 04 Y:1999 | 04 | 1999 | USE A DIFFERENT OR RECYCLED RAW MATERIAL | $12,000 | $17,070 | n/a |