Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,754
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0523 # 01 Y:1997 | 01 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $24,325 | $132,000 | Not Implemented |
OK0523 # 02 Y:1997 | 02 | 1997 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $65,338 | $74,935 | Implemented |
OK0523 # 03 Y:1997 | 03 | 1997 | INSTALL OCCUPANCY SENSORS | $1,405 | $1,188 | Not Implemented |
OK0523 # 04 Y:1997 | 04 | 1997 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $72,212 | $16,000 | Implemented |
OK0523 # 05 Y:1997 | 05 | 1997 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $2,478 | $6,900 | Implemented |
OK0523 # 06 Y:1997 | 06 | 1997 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,326 | $1,658 | Not Implemented |
OK0523 # 07 Y:1997 | 07 | 1997 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,077 | $0 | Implemented |
OK0522 # 01 Y:1997 | 01 | 1997 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $844 | $2,845 | Implemented |
OK0522 # 02 Y:1997 | 02 | 1997 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $1,918 | $3,500 | Implemented |
OK0522 # 03 Y:1997 | 03 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $103 | $200 | Implemented |
OK0522 # 04 Y:1997 | 04 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $-70 | $386 | Implemented |
OK0522 # 05 Y:1997 | 05 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $282 | $880 | Not Implemented |
OK0522 # 06 Y:1997 | 06 | 1997 | RECOVER AND REUSE WASTE MATERIAL | $54,126 | $4,480 | Not Implemented |
OK0522 # 07 Y:1997 | 07 | 1997 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $198 | $0 | Not Implemented |
OK0522 # 08 Y:1997 | 08 | 1997 | ELIMINATE SHIFT | $10,400 | $200 | Implemented |
OK0522 # 09 Y:1997 | 09 | 1997 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $4,662 | $15,500 | Not Implemented |
OK0521 # 01 Y:1997 | 01 | 1997 | INCREASE USE OF AUTOMATION | $66,300 | $200,000 | Not Implemented |
OK0521 # 02 Y:1997 | 02 | 1997 | DISTILL CONTAMINATED SOLVENTS FOR REUSE | $5,370 | $1,320 | Not Implemented |
OK0521 # 03 Y:1997 | 03 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,798 | $9,384 | Not Implemented |
OK0521 # 04 Y:1997 | 04 | 1997 | INSTALL AUTOMATIC STACK DAMPER | $679 | $847 | Not Implemented |
OK0521 # 05 Y:1997 | 05 | 1997 | INSTALL OCCUPANCY SENSORS | $220 | $622 | Not Implemented |
OK0521 # 06 Y:1997 | 06 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $100 | $161 | Not Implemented |
OK0518 # 01 Y:1997 | 01 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,774 | $17,415 | Implemented |
OK0518 # 02 Y:1997 | 02 | 1997 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $7,965 | $5,000 | Implemented |
OK0518 # 03 Y:1997 | 03 | 1997 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $6,577 | $8,566 | Not Implemented |