Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,002
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MI0218 # 08 Y:2012 | 08 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $10,055 | $80 | Implemented |
MI0218 # 09 Y:2012 | 09 | 2012 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $8,885 | $13,800 | Not Implemented |
LE0335 # 01 Y:2012 | 01 | 2012 | USE EXISTING DAM TO GENERATE ELECTRICITY | $1,144,296 | $10,386,800 | Not Implemented |
LE0335 # 02 Y:2012 | 02 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $67,090 | $3,825 | Not Implemented |
LE0335 # 03 Y:2012 | 03 | 2012 | INSTALL SOFT-START TO ELIMINATE NUISANCE TRIPS | $19,961 | $32,500 | Not Implemented |
LE0335 # 04 Y:2012 | 04 | 2012 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $15,946 | $9,800 | Not Implemented |
LE0335 # 05 Y:2012 | 05 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $11,640 | $1,000 | Not Implemented |
LE0335 # 06 Y:2012 | 06 | 2012 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $7,534 | $3,000 | Not Implemented |
LE0335 # 07 Y:2012 | 07 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $41,018 | $44,640 | Not Implemented |
LE0335 # 08 Y:2012 | 08 | 2012 | INSTALL TIMERS AND/OR THERMOSTATS | $516 | $125 | Not Implemented |
AM0607 # 01 Y:2012 | 01 | 2012 | OPTIMIZE PLANT POWER FACTOR | $42,700 | $60,200 | Implemented |
AM0607 # 02 Y:2012 | 02 | 2012 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $109,000 | $10,900 | Implemented |
AM0607 # 03 Y:2012 | 03 | 2012 | PAY UTILITY BILLS ON TIME | $9,700 | $0 | Implemented |
AM0607 # 04 Y:2012 | 04 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,300 | $17,365 | Implemented |
AM0607 # 05 Y:2012 | 05 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,510 | $620 | Implemented |
AM0607 # 06 Y:2012 | 06 | 2012 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $12,130 | $1,200 | Implemented |
AM0607 # 07 Y:2012 | 07 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $830 | $500 | Not Implemented |
AM0607 # 08 Y:2012 | 08 | 2012 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $100 | $0 | Implemented |
AM0608 # 01 Y:2012 | 01 | 2012 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $1,383,679 | $251,064 | Implemented |
AM0608 # 02 Y:2012 | 02 | 2012 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $90,500 | $180,000 | Not Implemented |
AM0608 # 03 Y:2012 | 03 | 2012 | RECOVER AND REUSE WASTE MATERIAL | $144,150 | $85,000 | Implemented |
AM0608 # 04 Y:2012 | 04 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $52,200 | $124,000 | Implemented |
AM0608 # 05 Y:2012 | 05 | 2012 | INSTALL OCCUPANCY SENSORS | $12,691 | $3,566 | Not Implemented |
AM0608 # 06 Y:2012 | 06 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,360 | $65 | Not Implemented |
AM0608 # 07 Y:2012 | 07 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,900 | $1,625 | Implemented |