Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,059
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WI0329 # 07 Y:1998 | 07 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $626 | $640 | Implemented |
WI0325 # 01 Y:1998 | 01 | 1998 | INSTALL AUTOMATIC PACKING EQUIPMENT | $336,000 | $240,000 | Not Implemented |
WI0325 # 02 Y:1998 | 02 | 1998 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $7,848 | $500 | Implemented |
WI0325 # 03 Y:1998 | 03 | 1998 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $7,598 | $10,000 | Not Implemented |
WI0325 # 04 Y:1998 | 04 | 1998 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $5,590 | $0 | Not Implemented |
WI0325 # 05 Y:1998 | 05 | 1998 | OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES | $1,652 | $0 | Not Implemented |
WI0325 # 06 Y:1998 | 06 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $756 | $740 | Not Implemented |
WI0322 # 06 Y:1998 | 06 | 1998 | SHIFT FROM DAYTIME TO NIGHTTIME OPERATION | $3,817 | $0 | Not Implemented |
WI0322 # 07 Y:1998 | 07 | 1998 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $1,087 | $600 | Not Implemented |
WI0322 # 08 Y:1998 | 08 | 1998 | OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES | $2,376 | $0 | Not Implemented |
WI0322 # 09 Y:1998 | 09 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $343 | $740 | Not Implemented |
WI0322 # 01 Y:1998 | 01 | 1998 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $21,516 | $1,000 | Not Implemented |
WI0322 # 02 Y:1998 | 02 | 1998 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $11,052 | $500 | Not Implemented |
WI0322 # 03 Y:1998 | 03 | 1998 | INSTALL TIMERS AND/OR THERMOSTATS | $6,348 | $1,000 | Not Implemented |
WI0322 # 04 Y:1998 | 04 | 1998 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $4,205 | $4,500 | Not Implemented |
WI0322 # 05 Y:1998 | 05 | 1998 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $4,677 | $9,000 | Not Implemented |
WI0320 # 01 Y:1998 | 01 | 1998 | MOVE PRODUCT USING MECHANICAL MEANS | $98,187 | $100,000 | Not Implemented |
WI0320 # 02 Y:1998 | 02 | 1998 | INSTALL TIMERS AND/OR THERMOSTATS | $4,771 | $600 | Not Implemented |
WI0320 # 03 Y:1998 | 03 | 1998 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $3,933 | $6,400 | Not Implemented |
WI0320 # 04 Y:1998 | 04 | 1998 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $3,532 | $0 | Not Implemented |
WI0320 # 05 Y:1998 | 05 | 1998 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,433 | $7,000 | Not Implemented |
WI0320 # 06 Y:1998 | 06 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $650 | $740 | Implemented |
WI0319 # 01 Y:1998 | 01 | 1998 | INSTALL SENSORS TO DETECT DEFECTS | $69,212 | $63,760 | Not Implemented |
WI0319 # 02 Y:1998 | 02 | 1998 | DISTILL CONTAMINATED SOLVENTS FOR REUSE | $6,046 | $13,200 | Not Implemented |
WI0319 # 03 Y:1998 | 03 | 1998 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $4,599 | $18,400 | Not Implemented |