IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

5,754

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0497 # 04 Y:1996 04 1996 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,106 $1,965 Not Implemented
OK0497 # 05 Y:1996 05 1996 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $187 $50 Implemented
OK0496 # 01 Y:1996 01 1996 PURCHASE HIGH MATERIALS IN RETURNABLE BULK CONTAINERS $32,272 $140,000 Implemented
OK0496 # 02 Y:1996 02 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,549 $3,017 Implemented
OK0496 # 03 Y:1996 03 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,697 $8,963 Implemented
OK0496 # 04 Y:1996 04 1996 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $1,930 $300 Not Implemented
OK0496 # 05 Y:1996 05 1996 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $502 $1,190 Not Implemented
OK0496 # 06 Y:1996 06 1996 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $145 $0 Implemented
OK0493 # 01 Y:1996 01 1996 TURN OFF EQUIPMENT WHEN NOT IN USE $92 $100 Implemented
OK0493 # 02 Y:1996 02 1996 USE PHOTOCELL CONTROLS $237 $90 Not Implemented
OK0493 # 03 Y:1996 03 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,380 $1,416 Implemented
OK0493 # 04 Y:1996 04 1996 RECOVER WASTE HEAT FROM EQUIPMENT $1,474 $277 Not Implemented
OK0493 # 05 Y:1996 05 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $143 $321 Implemented
OK0493 # 06 Y:1996 06 1996 RECYCLE CLEANING SOLVENT AND REUSE $6,123 $500 Not Implemented
OK0493 # 07 Y:1996 07 1996 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $64 $60 Implemented
OK0493 # 08 Y:1996 08 1996 INSTALL OCCUPANCY SENSORS $113 $336 Not Implemented
OK0495 # 01 Y:1996 01 1996 INSTALL SET-BACK TIMERS $5,943 $1,050 Implemented
OK0495 # 02 Y:1996 02 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $66 $228 Not Implemented
OK0495 # 03 Y:1996 03 1996 INSTALL SPECTRAL REFLECTORS / DELAMP $854 $65 Not Implemented
OK0495 # 04 Y:1996 04 1996 INSTALL OCCUPANCY SENSORS $104 $132 Not Implemented
OK0495 # 05 Y:1996 05 1996 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $232 $244 Implemented
OK0495 # 06 Y:1996 06 1996 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $246 $120 Implemented
OK0495 # 07 Y:1996 07 1996 TREAT AND REUSE RINSE WATERS $3,524 $40,000 Implemented
OK0492 # 01 Y:1996 01 1996 INSULATE BARE EQUIPMENT $2,709 $3,419 Implemented
OK0492 # 02 Y:1996 02 1996 ADJUST BURNERS FOR EFFICIENT OPERATION $1,502 $500 Implemented