Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,754
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0487 # 02 Y:1996 | 02 | 1996 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $2,235 | $4,100 | Implemented |
OK0487 # 03 Y:1996 | 03 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,133 | $1,460 | Implemented |
OK0487 # 04 Y:1996 | 04 | 1996 | SIZE AIR HANDLING GRILLS/ DUCT/S COILS TO MINIMIZE AIR RESISTANCE | $935 | $2,000 | Not Implemented |
OK0487 # 05 Y:1996 | 05 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $213 | $400 | Implemented |
OK0487 # 06 Y:1996 | 06 | 1996 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $11,121 | $2,000 | Implemented |
OK0487 # 07 Y:1996 | 07 | 1996 | BURN WOOD BY-PRODUCTS FOR HEAT | $2,800 | $1,500 | Implemented |
OK0487 # 08 Y:1996 | 08 | 1996 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $1,650 | $0 | Implemented |
OK0485 # 01 Y:1996 | 01 | 1996 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $10,114 | $23,322 | Not Implemented |
OK0485 # 02 Y:1996 | 02 | 1996 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $1,827 | $2,730 | Implemented |
OK0485 # 03 Y:1996 | 03 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $428 | $786 | Implemented |
OK0485 # 04 Y:1996 | 04 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $131 | $395 | Not Implemented |
OK0485 # 05 Y:1996 | 05 | 1996 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $6,970 | $29,500 | Implemented |
OK0484 # 01 Y:1996 | 01 | 1996 | INSTALL SET-BACK TIMERS | $12,501 | $1,360 | Implemented |
OK0484 # 02 Y:1996 | 02 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $249 | $550 | Implemented |
OK0484 # 03 Y:1996 | 03 | 1996 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $52 | $0 | Implemented |
OK0484 # 04 Y:1996 | 04 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $131 | $395 | Not Implemented |
OK0484 # 05 Y:1996 | 05 | 1996 | USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES | $7,114 | $7,475 | Not Implemented |
OK0483 # 04 Y:1996 | 04 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $838 | $786 | Implemented |
OK0483 # 05 Y:1996 | 05 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $434 | $1,779 | Implemented |
OK0483 # 06 Y:1996 | 06 | 1996 | BURN WOOD BY-PRODUCTS FOR HEAT | $28,560 | $29,500 | Implemented |
OK0486 # 01 Y:1996 | 01 | 1996 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,955 | $5,951 | Not Implemented |
OK0486 # 02 Y:1996 | 02 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $5,401 | $3,275 | Implemented |
OK0486 # 03 Y:1996 | 03 | 1996 | IMPROVE LUBRICATION PRACTICES | $4,213 | $0 | Not Implemented |
OK0486 # 04 Y:1996 | 04 | 1996 | UPGRADE CONTROLS ON COMPRESSORS | $1,548 | $5,600 | Implemented |
OK0486 # 05 Y:1996 | 05 | 1996 | DISCONNECT BALLASTS | $428 | $1,060 | Implemented |