Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,204
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0416 # 04 Y:2006 | 04 | 2006 | USE DRYING OVEN (BATCH TYPE) ON ALTERNATE DAYS OR OTHER OPTIMUM SCHEDULE TO RUN EQUIPMENT WITH FULL LOADS | $1,237 | $0 | Not Implemented |
AS0416 # 05 Y:2006 | 05 | 2006 | USE SOLAR HEAT TO HEAT WATER | $345 | $2,050 | Not Implemented |
WI0509 # 01 Y:2006 | 01 | 2006 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $34,120 | $25,000 | Not Implemented |
WI0509 # 02 Y:2006 | 02 | 2006 | USE CLEAN IN PLACE (CIP) SYSTEMS | $24,741 | $37,800 | Not Implemented |
WI0509 # 03 Y:2006 | 03 | 2006 | INSTALL TIMERS AND/OR THERMOSTATS | $6,741 | $0 | Not Implemented |
WI0509 # 04 Y:2006 | 04 | 2006 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,107 | $1,000 | Not Implemented |
WI0509 # 05 Y:2006 | 05 | 2006 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,764 | $640 | Not Implemented |
WI0509 # 06 Y:2006 | 06 | 2006 | COOL COMPRESSOR AIR INTAKE WITH HEAT EXCHANGER | $1,330 | $0 | Not Implemented |
WI0509 # 07 Y:2006 | 07 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,189 | $0 | Not Implemented |
WI0509 # 08 Y:2006 | 08 | 2006 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $3,886 | $3,886 | Not Implemented |
WI0509 # 09 Y:2006 | 09 | 2006 | RECOVER WASTE HEAT FROM EQUIPMENT | $769 | $400 | Not Implemented |
BD0303 # 01 Y:2006 | 01 | 2006 | USE RADIANT HEATER FOR SPOT HEATING | $9,279 | $8,400 | Not Implemented |
BD0303 # 02 Y:2006 | 02 | 2006 | INSTALL MOTOR VOLTAGE CONTROLLER ON LIGHTLY LOADED MOTORS | $2,839 | $4,020 | Not Implemented |
BD0303 # 03 Y:2006 | 03 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,511 | $1,500 | Implemented |
BD0303 # 04 Y:2006 | 04 | 2006 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,403 | $400 | Implemented |
BD0303 # 05 Y:2006 | 05 | 2006 | USE SYNTHETIC LUBRICANT | $1,275 | $1,500 | Implemented |
BD0303 # 06 Y:2006 | 06 | 2006 | USE PHOTOCELL CONTROLS | $903 | $2,000 | Not Implemented |
BD0303 # 07 Y:2006 | 07 | 2006 | INSTALL OCCUPANCY SENSORS | $168 | $225 | Not Implemented |
SF0323 # 01 Y:2006 | 01 | 2006 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $8,385 | $4,000 | Not Implemented |
SF0323 # 02 Y:2006 | 02 | 2006 | INSULATE BARE EQUIPMENT | $5,614 | $1,181 | Not Implemented |
SF0323 # 03 Y:2006 | 03 | 2006 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $6,718 | $3,434 | Implemented |
SF0323 # 04 Y:2006 | 04 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,432 | $8,974 | Implemented |
SF0323 # 05 Y:2006 | 05 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,123 | $5,355 | Not Implemented |
SF0323 # 06 Y:2006 | 06 | 2006 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $117,125 | $345,000 | Not Implemented |
SF0323 # 07 Y:2006 | 07 | 2006 | INSTALL SKYLIGHTS | $13,832 | $47,430 | Not Implemented |