IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

4,184

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
ND0220 # 01 Y:1995 01 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $3,210 $2,390 Not Implemented
ND0220 # 02 Y:1995 02 1995 OPTIMIZE PLANT POWER FACTOR $1,783 $2,145 Not Implemented
ND0220 # 03 Y:1995 03 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,400 $374 Implemented
ND0220 # 04 Y:1995 04 1995 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,167 $400 Implemented
ND0220 # 05 Y:1995 05 1995 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $341 $100 Implemented
ND0220 # 06 Y:1995 06 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $127 $190 Not Implemented
ND0220 # 07 Y:1995 07 1995 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS $117 $70 Implemented
ND0220 # 08 Y:1995 08 1995 TURN OFF EQUIPMENT WHEN NOT IN USE $87 $0 Implemented
ND0218 # 01 Y:1995 01 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $328 $267 Implemented
ND0218 # 02 Y:1995 02 1995 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,338 $875 Implemented
ND0218 # 03 Y:1995 03 1995 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,030 $800 Not Implemented
ND0218 # 04 Y:1995 04 1995 TURN OFF EQUIPMENT WHEN NOT IN USE $27,861 $0 Implemented
ND0218 # 05 Y:1995 05 1995 TURN OFF EQUIPMENT WHEN NOT IN USE $156 $1,000 Not Implemented
ND0218 # 06 Y:1995 06 1995 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $9,684 $0 Not Implemented
ND0218 # 07 Y:1995 07 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,828 $970 Implemented
ND0218 # 08 Y:1995 08 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $176 $440 Not Implemented
ND0215 # 01 Y:1995 01 1995 TURN OFF EQUIPMENT WHEN NOT IN USE $144 $0 Implemented
ND0215 # 02 Y:1995 02 1995 SUBSTITUTE COMPRESSED AIR COOLING WITH WATER OR AIR COOLING $8,721 $200 Not Implemented
ND0215 # 03 Y:1995 03 1995 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,150 $600 Not Implemented
ND0215 # 04 Y:1995 04 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,186 $682 Implemented
ND0215 # 05 Y:1995 05 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $20,050 $14,480 Not Implemented
ND0215 # 06 Y:1995 06 1995 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $98 $150 Implemented
ND0215 # 07 Y:1995 07 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $40 $285 Not Implemented
ND0213 # 01 Y:1995 01 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $23,611 $48,290 Implemented
ND0213 # 02 Y:1995 02 1995 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $9,837 $5,000 Not Implemented