IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

494

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SD0217 # 10 Y:1999 10 1999 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $1,680 $0 Not Implemented
SD0217 # 11 Y:1999 11 1999 CONVERT TO ELECTROSTATIC POWDER COATING $147,960 $10,000 Implemented
SD0217 # 12 Y:1999 12 1999 $4,000 $8,000 Not Implemented
SD0217 # 13 Y:1999 13 1999 $12,000 $21,920 Not Implemented
SD0217 # 14 Y:1999 14 1999 MINIMIZE WATER USAGE $1,451 $0 Not Implemented
SD0217 # 15 Y:1999 15 1999 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL $5,580 $0 Implemented
SD0216 # 01 Y:1999 01 1999 INSTALL SPECTRAL REFLECTORS / DELAMP $1,277 $1,650 Implemented
SD0216 # 02 Y:1999 02 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $11,961 $1,060 Implemented
SD0216 # 03 Y:1999 03 1999 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $99,648 $111,600 Not Implemented
SD0216 # 04 Y:1999 04 1999 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $840 $0 Implemented
SD0216 # 05 Y:1999 05 1999 USE EVAPORATION TO CONCENTRATE MATERIAL $1,038 $1,500 Not Implemented
SD0216 # 06 Y:1999 06 1999 CONVERT TO AQUEOUS CLEANING $6,009 $6,009 Not Implemented
SD0216 # 07 Y:1999 07 1999 $11,740 $4,100 Not Implemented
SD0216 # 08 Y:1999 08 1999 $25,245 $22,970 Not Implemented
SF0162 # 01 Y:1999 01 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $615 $0 Implemented
SF0162 # 02 Y:1999 02 1999 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $7,561 $2,700 Implemented
SF0162 # 03 Y:1999 03 1999 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $453 $291 Implemented
SF0162 # 04 Y:1999 04 1999 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $3,921 $3,189 Implemented
SF0162 # 05 Y:1999 05 1999 INSTALL OCCUPANCY SENSORS $1,105 $1,008 Not Implemented
SF0162 # 06 Y:1999 06 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,910 $8,190 Implemented
SF0162 # 07 Y:1999 07 1999 USE PHOTOCELL CONTROLS $2,025 $6,000 Not Implemented
SF0162 # 08 Y:1999 08 1999 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,014 $4,121 Implemented
SD0215 # 01 Y:1999 01 1999 INSTALL SPECTRAL REFLECTORS / DELAMP $3,652 $3,480 Not Implemented
SD0215 # 02 Y:1999 02 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,635 $6,257 Implemented
SD0215 # 03 Y:1999 03 1999 INSULATE BARE EQUIPMENT $1,080 $906 Not Implemented