Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,872
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0213 # 10 Y:1998 | 10 | 1998 | APPLY FOR INVESTMENT INCENTIVES | $21,947 | $50 | Not Implemented |
MS0124 # 01 Y:1998 | 01 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,313 | $15,976 | Not Implemented |
MS0124 # 02 Y:1998 | 02 | 1998 | INSTALL TIMERS AND/OR THERMOSTATS | $2,507 | $944 | Implemented |
MS0124 # 03 Y:1998 | 03 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $740 | $400 | Implemented |
MS0124 # 04 Y:1998 | 04 | 1998 | INSTALL SHELVES / RACKS TO UTILIZE UNUSED SPACE | $4,500 | $2,888 | Implemented |
MS0124 # 05 Y:1998 | 05 | 1998 | ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL | $35,438 | $25,290 | Not Implemented |
MS0124 # 06 Y:1998 | 06 | 1998 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $51 | $14 | Implemented |
UL0209 # 01 Y:1998 | 01 | 1998 | INSTALL TIMERS AND/OR THERMOSTATS | $2,561 | $2,000 | Not Implemented |
UL0209 # 02 Y:1998 | 02 | 1998 | USE DRYING OVEN (BATCH TYPE) ON ALTERNATE DAYS OR OTHER OPTIMUM SCHEDULE TO RUN EQUIPMENT WITH FULL LOADS | $4,743 | $0 | Not Implemented |
UL0209 # 03 Y:1998 | 03 | 1998 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,173 | $0 | Implemented |
UL0209 # 04 Y:1998 | 04 | 1998 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $2,442 | $0 | Not Implemented |
UL0209 # 05 Y:1998 | 05 | 1998 | ELIMINATE/REDUCE REDUNDANT INSPECTIONS | $4,330 | $78 | Implemented |
MS0122 # 01 Y:1998 | 01 | 1998 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $19,058 | $2,430 | Implemented |
MS0122 # 02 Y:1998 | 02 | 1998 | OPTIMIZE PLANT POWER FACTOR | $2,247 | $4,950 | Implemented |
MS0122 # 03 Y:1998 | 03 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,048 | $16,228 | Not Implemented |
MS0122 # 04 Y:1998 | 04 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,881 | $520 | Implemented |
MS0122 # 05 Y:1998 | 05 | 1998 | INSTALL TIMERS AND/OR THERMOSTATS | $896 | $472 | Not Implemented |
MS0122 # 06 Y:1998 | 06 | 1998 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $2,782 | $25 | Implemented |
MS0122 # 07 Y:1998 | 07 | 1998 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $107,455 | $7,165 | Not Implemented |
MS0122 # 08 Y:1998 | 08 | 1998 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $2,652 | $2,025 | Implemented |
MS0122 # 09 Y:1998 | 09 | 1998 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $9,648 | $2,025 | Implemented |
NC0153 # 01 Y:1998 | 01 | 1998 | RECOVER WASTE HEAT FROM EQUIPMENT | $541 | $800 | Not Implemented |
NC0153 # 02 Y:1998 | 02 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $16,691 | $18,850 | Not Implemented |
NC0153 # 03 Y:1998 | 03 | 1998 | ADD AREA LIGHTING SWITCHES | $91 | $300 | Not Implemented |
NC0153 # 04 Y:1998 | 04 | 1998 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $3,508 | $500 | Not Implemented |