Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,754
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0205 # 01 Y:1986 | 01 | 1986 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $855 | $643 | Implemented |
OK0205 # 02 Y:1986 | 02 | 1986 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $670 | $428 | Implemented |
OK0205 # 03 Y:1986 | 03 | 1986 | ENHANCE SENSITIVITY OF TEMPERATURE CONTROL AND CUTOFF | $3,130 | $10,000 | Not Implemented |
OK0206 # 01 Y:1986 | 01 | 1986 | UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM | $1,270 | $3,500 | Implemented |
OK0206 # 02 Y:1986 | 02 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,340 | $1,056 | Implemented |
OK0206 # 03 Y:1986 | 03 | 1986 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $743 | $4,000 | Implemented |
OK0207 # 01 Y:1986 | 01 | 1986 | KEEP LAMPS AND REFLECTORS CLEAN | $10,632 | $24,429 | Implemented |
OK0207 # 02 Y:1986 | 02 | 1986 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $153 | $87 | Implemented |
OK0207 # 03 Y:1986 | 03 | 1986 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $24 | $4 | Implemented |
OK0207 # 04 Y:1986 | 04 | 1986 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $2,124 | $8,200 | Implemented |
OK0207 # 05 Y:1986 | 05 | 1986 | ENHANCE SENSITIVITY OF TEMPERATURE CONTROL AND CUTOFF | $2,466 | $1,200 | Implemented |
OK0195 # 01 Y:1986 | 01 | 1986 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,989 | $500 | Implemented |
OK0195 # 02 Y:1986 | 02 | 1986 | USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD | $2,085 | $214 | Not Implemented |
OK0195 # 03 Y:1986 | 03 | 1986 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $2,520 | $3,000 | Implemented |
OK0195 # 04 Y:1986 | 04 | 1986 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $12,902 | $0 | Implemented |
OK0195 # 05 Y:1986 | 05 | 1986 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $1,289 | $1,200 | Implemented |
OK0195 # 06 Y:1986 | 06 | 1986 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $582 | $0 | Implemented |
OK0195 # 07 Y:1986 | 07 | 1986 | ENHANCE SENSITIVITY OF TEMPERATURE CONTROL AND CUTOFF | $2,030 | $1,200 | Implemented |
OK0196 # 01 Y:1986 | 01 | 1986 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,521 | $0 | Implemented |
OK0196 # 02 Y:1986 | 02 | 1986 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $693 | $1,821 | Implemented |
OK0196 # 03 Y:1986 | 03 | 1986 | USE RADIANT HEATER FOR SPOT HEATING | $7,663 | $36,000 | Not Implemented |
OK0197 # 01 Y:1986 | 01 | 1986 | MINIMIZE BOILER BLOWDOWN WITH BETTER FEEDWATER TREATMENT | $2,964 | $3,200 | Implemented |
OK0197 # 02 Y:1986 | 02 | 1986 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $369 | $360 | Not Implemented |
OK0197 # 03 Y:1986 | 03 | 1986 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,954 | $1,500 | Not Implemented |
OK0197 # 04 Y:1986 | 04 | 1986 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $547 | $80 | Implemented |