Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,105
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LL0155 # 08 Y:2003 | 08 | 2003 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $1,006 | $186 | Implemented |
AM0429 # 01 Y:2003 | 01 | 2003 | REPLACE OLD MACHINE WITH NEW AUTOMATIC MULTI-STATION TOOL | $13,000 | $0 | Not Implemented |
AM0429 # 02 Y:2003 | 02 | 2003 | CHECK FOR ACCURACY OF UTILITY / POWER METERS | $2,770 | $7,800 | Not Implemented |
AM0429 # 03 Y:2003 | 03 | 2003 | UPGRADE OBSOLETE EQUIPMENT | $830 | $6,540 | Not Implemented |
AM0429 # 04 Y:2003 | 04 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $500 | $200 | Implemented |
AM0429 # 05 Y:2003 | 05 | 2003 | USE SYNTHETIC LUBRICANT | $101 | $0 | Not Implemented |
UF0314 # 01 Y:2003 | 01 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,414 | $8,936 | Implemented |
UF0314 # 02 Y:2003 | 02 | 2003 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,569 | $2,000 | Not Implemented |
UF0314 # 03 Y:2003 | 03 | 2003 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $51,357 | $165,670 | Not Implemented |
UF0314 # 04 Y:2003 | 04 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $84,571 | $191,945 | Implemented |
UF0314 # 05 Y:2003 | 05 | 2003 | INSULATE BARE EQUIPMENT | $29,609 | $3,005 | Not Implemented |
UF0314 # 06 Y:2003 | 06 | 2003 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $375,940 | $302,000 | Not Implemented |
UF0314 # 07 Y:2003 | 07 | 2003 | INSTALL AUTOMATIC PACKING EQUIPMENT | $135,000 | $32,000 | Not Implemented |
WI0436 # 01 Y:2003 | 01 | 2003 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $28,363 | $102,600 | Not Implemented |
WI0436 # 02 Y:2003 | 02 | 2003 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $3,768 | $200 | Not Implemented |
WI0436 # 03 Y:2003 | 03 | 2003 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $3,276 | $1,424 | Not Implemented |
WI0436 # 04 Y:2003 | 04 | 2003 | INSTALL TIMERS AND/OR THERMOSTATS | $861 | $800 | Not Implemented |
WI0436 # 05 Y:2003 | 05 | 2003 | INSTALL OCCUPANCY SENSORS | $496 | $225 | Not Implemented |
WI0436 # 06 Y:2003 | 06 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $212 | $272 | Not Implemented |
WI0436 # 07 Y:2003 | 07 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $119 | $34 | Implemented |
SD0312 # 01 Y:2003 | 01 | 2003 | USE PHOTOCELL CONTROLS | $16,275 | $11,000 | Not Implemented |
SD0312 # 02 Y:2003 | 02 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,368 | $0 | Not Implemented |
SD0312 # 03 Y:2003 | 03 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,675 | $400 | Not Implemented |
SD0312 # 04 Y:2003 | 04 | 2003 | TURN OFF EQUIPMENT WHEN NOT IN USE | $781 | $0 | Implemented |
SD0312 # 05 Y:2003 | 05 | 2003 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $7,500 | $10,000 | Not Implemented |