Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
84
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0396 # 04 Y:1997 | 04 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,606 | $75 | Implemented |
MA0396 # 02 Y:1997 | 02 | 1997 | INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) | $5,492 | $11,700 | Implemented |
MA0396 # 05 Y:1997 | 05 | 1997 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,409 | $60 | Implemented |
MA0396 # 03 Y:1997 | 03 | 1997 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $4,207 | $14,329 | Not Implemented |
MA0396 # 06 Y:1997 | 06 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $819 | $102 | Not Implemented |
MA0396 # 01 Y:1997 | 01 | 1997 | USE MAGNETIC TECHNOLOGY TO TREAT WATER | $7,580 | $9,347 | Not Implemented |
MA0395 # 06 Y:1997 | 06 | 1997 | USE MAGNETIC TECHNOLOGY TO TREAT WATER | $825 | $5,200 | Not Implemented |
MA0395 # 04 Y:1997 | 04 | 1997 | $1,153 | $0 | Implemented | |
MA0395 # 03 Y:1997 | 03 | 1997 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $20 | $0 | Implemented |
MA0395 # 02 Y:1997 | 02 | 1997 | BURN A LESS EXPENSIVE GRADE OF FUEL | $440 | $0 | Not Implemented |
MA0395 # 01 Y:1997 | 01 | 1997 | $8,941 | $16,900 | Not Implemented | |
MA0395 # 05 Y:1997 | 05 | 1997 | INSTALL OCCUPANCY SENSORS | $888 | $992 | Implemented |
MA0390 # 03 Y:1997 | 03 | 1997 | OPTIMIZE PLANT POWER FACTOR | $4,435 | $9,975 | Not Implemented |
MA0390 # 04 Y:1997 | 04 | 1997 | CHECK FOR ACCURACY OF UTILITY / POWER METERS | $3,585 | $480 | Not Implemented |
MA0390 # 05 Y:1997 | 05 | 1997 | INSTALL OCCUPANCY SENSORS | $852 | $999 | Not Implemented |
MA0390 # 06 Y:1997 | 06 | 1997 | CONVERT TO AQUEOUS CLEANING | $548 | $0 | Not Implemented |
MA0390 # 02 Y:1997 | 02 | 1997 | $5,709 | $0 | Not Implemented | |
MA0390 # 01 Y:1997 | 01 | 1997 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $12,319 | $11,700 | Not Implemented |
MA0389 # 06 Y:1997 | 06 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $298 | $75 | Implemented |
MA0389 # 05 Y:1997 | 05 | 1997 | CHECK FOR ACCURACY OF UTILITY / POWER METERS | $538 | $60 | Implemented |
MA0389 # 04 Y:1997 | 04 | 1997 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $565 | $0 | Implemented |
MA0389 # 03 Y:1997 | 03 | 1997 | INSTALL / REPAIR INSULATION ON STEAM LINES | $592 | $860 | Implemented |
MA0389 # 02 Y:1997 | 02 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,610 | $2,100 | Not Implemented |
MA0389 # 01 Y:1997 | 01 | 1997 | $2,061 | $0 | Not Implemented | |
MA0391 # 06 Y:1997 | 06 | 1997 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $947 | $520 | Not Implemented |