Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,715
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0577 # 02 Y:2016 | 02 | 2016 | USE DIRECT AIR SUPPLY TO EXHAUST HOODS | $11,227 | $15,000 | Not Implemented |
NC0577 # 03 Y:2016 | 03 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $819 | $100 | Not Implemented |
NC0577 # 04 Y:2016 | 04 | 2016 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,088 | $3,600 | Not Implemented |
NC0577 # 05 Y:2016 | 05 | 2016 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,896 | $100 | Not Implemented |
NC0577 # 06 Y:2016 | 06 | 2016 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,793 | $2,000 | Not Implemented |
NC0577 # 07 Y:2016 | 07 | 2016 | INSULATE BARE EQUIPMENT | $168 | $799 | Not Implemented |
NC0577 # 08 Y:2016 | 08 | 2016 | REPAIR AND ELIMINATE STEAM LEAKS | $106 | $200 | Not Implemented |
NC0577 # 09 Y:2016 | 09 | 2016 | TREAT AND REUSE RINSE WATERS | $5,659 | $7,720 | Not Implemented |
IA0565 # 03 Y:2016 | 03 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,616 | $5,218 | Not Implemented |
IA0565 # 04 Y:2016 | 04 | 2016 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,371 | $500 | Implemented |
IA0565 # 05 Y:2016 | 05 | 2016 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,846 | $2,352 | Implemented |
IA0565 # 06 Y:2016 | 06 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,529 | $165 | Implemented |
IA0565 # 07 Y:2016 | 07 | 2016 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,046 | $70 | Implemented |
CO0735 # 01 Y:2016 | 01 | 2016 | UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM | $4,910 | $31,560 | n/a |
CO0735 # 02 Y:2016 | 02 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,020 | $13,690 | n/a |
CO0735 # 03 Y:2016 | 03 | 2016 | USE SOLAR HEAT TO MAKE ELECTRICTY | $2,820 | $14,180 | n/a |
CO0735 # 04 Y:2016 | 04 | 2016 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,500 | $1,860 | n/a |
IA0565 # 01 Y:2016 | 01 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $54,062 | $60,264 | Not Implemented |
IA0565 # 02 Y:2016 | 02 | 2016 | INSTALL OCCUPANCY SENSORS | $3,083 | $5,550 | Not Implemented |
SU0422 # 01 Y:2016 | 01 | 2016 | ELIMINATE/REDUCE AN OPERATION | $1,752 | $0 | Implemented |
SU0422 # 02 Y:2016 | 02 | 2016 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $450 | $0 | Not Implemented |
SU0422 # 03 Y:2016 | 03 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $484 | $164 | Implemented |
SU0422 # 04 Y:2016 | 04 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $153 | $150 | Implemented |
SU0422 # 05 Y:2016 | 05 | 2016 | ELIMINATE/REDUCE AN OPERATION | $880 | $960 | Not Implemented |
SU0422 # 06 Y:2016 | 06 | 2016 | REDUCE VENTILATION AIR | $846 | $880 | Not Implemented |