Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,872
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0103 # 05 Y:1998 | 05 | 1998 | SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE | $15,000 | $1,500 | Not Implemented |
UM0103 # 06 Y:1998 | 06 | 1998 | USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS | $1,435 | $4,535 | Not Implemented |
UM0103 # 07 Y:1998 | 07 | 1998 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $1,962 | $200 | Implemented |
MS0101 # 01 Y:1998 | 01 | 1998 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $1,713 | $5,100 | Not Implemented |
MS0101 # 02 Y:1998 | 02 | 1998 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $1,593 | $4,400 | Not Implemented |
MS0101 # 03 Y:1998 | 03 | 1998 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,386 | $1,000 | Implemented |
MS0101 # 04 Y:1998 | 04 | 1998 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $2,750 | $0 | Implemented |
MS0101 # 05 Y:1998 | 05 | 1998 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $2,012 | $816 | Not Implemented |
MS0101 # 06 Y:1998 | 06 | 1998 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $7,360 | $420 | Implemented |
MS0101 # 07 Y:1998 | 07 | 1998 | PAY BILLS ON TIME TO AVOID LATE FEES | $207 | $0 | Implemented |
MS0101 # 08 Y:1998 | 08 | 1998 | COMBINE UTILITY METERS | $420 | $1,225 | Implemented |
NV0096 # 01 Y:1998 | 01 | 1998 | INCREASE AMOUNT OF CONDENSATE RETURNED | $6,487 | $6,000 | Not Implemented |
NV0096 # 02 Y:1998 | 02 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $248 | $200 | Implemented |
NV0096 # 03 Y:1998 | 03 | 1998 | OPTIMIZE PLANT POWER FACTOR | $5,011 | $16,200 | Not Implemented |
NV0096 # 04 Y:1998 | 04 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,858 | $3,052 | Implemented |
NV0096 # 05 Y:1998 | 05 | 1998 | INSULATE BARE EQUIPMENT | $1,575 | $530 | Not Implemented |
NV0096 # 06 Y:1998 | 06 | 1998 | INSULATE BARE EQUIPMENT | $878 | $611 | Not Implemented |
NV0096 # 07 Y:1998 | 07 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $836 | $306 | Implemented |
NV0096 # 08 Y:1998 | 08 | 1998 | USE PHOTOCELL CONTROLS | $713 | $290 | Not Implemented |
NV0096 # 09 Y:1998 | 09 | 1998 | USE PHOTOCELL CONTROLS | $2,820 | $580 | Not Implemented |
NV0096 # 10 Y:1998 | 10 | 1998 | INSTALL TIMERS AND/OR THERMOSTATS | $252 | $150 | Not Implemented |
NV0096 # 11 Y:1998 | 11 | 1998 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $326 | $0 | Not Implemented |
NV0096 # 12 Y:1998 | 12 | 1998 | RECOVER WASTE HEAT FROM EQUIPMENT | $129,993 | $113,670 | Not Implemented |
NV0096 # 13 Y:1998 | 13 | 1998 | RECOVER METALS FROM SPENT SOLUTIONS AND RECYCLE | $1,500 | $0 | Not Implemented |
ME0231 # 01 Y:1998 | 01 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,324 | $1,486 | Implemented |