Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,533
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0492 # 08 Y:2005 | 08 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,984 | $7,300 | Implemented |
OR0492 # 09 Y:2005 | 09 | 2005 | OPTIMIZE PLANT POWER FACTOR | $2,200 | $10,000 | Implemented |
NC0325 # 01 Y:2005 | 01 | 2005 | INCREASE AMOUNT OF CONDENSATE RETURNED | $27,917 | $25,000 | Not Implemented |
NC0325 # 02 Y:2005 | 02 | 2005 | ADJUST BURNERS FOR EFFICIENT OPERATION | $222,508 | $100,000 | Not Implemented |
NC0325 # 03 Y:2005 | 03 | 2005 | INSTALL / REPAIR INSULATION ON STEAM LINES | $9,902 | $18,198 | Not Implemented |
NC0325 # 04 Y:2005 | 04 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $423 | $1,006 | Not Implemented |
NC0325 # 05 Y:2005 | 05 | 2005 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,395 | $2,000 | Not Implemented |
NC0325 # 06 Y:2005 | 06 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,733 | $7,500 | Not Implemented |
TA0103 # 01 Y:2005 | 01 | 2005 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $12,460 | $8,170 | Not Implemented |
TA0103 # 02 Y:2005 | 02 | 2005 | REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS | $1,365 | $2,620 | Implemented |
TA0103 # 03 Y:2005 | 03 | 2005 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $14,113 | $0 | Implemented |
TA0103 # 04 Y:2005 | 04 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,990 | $0 | Implemented |
TA0103 # 05 Y:2005 | 05 | 2005 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $700 | $1,070 | Implemented |
OK0717 # 01 Y:2005 | 01 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $38,551 | $53,370 | Implemented |
OK0717 # 02 Y:2005 | 02 | 2005 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $4,162 | $7,760 | Not Implemented |
OK0717 # 03 Y:2005 | 03 | 2005 | USE COMPRESSOR AIR FILTERS | $111 | $417 | Not Implemented |
OK0717 # 04 Y:2005 | 04 | 2005 | INSULATE BARE EQUIPMENT | $1,466 | $1,039 | Implemented |
OK0717 # 05 Y:2005 | 05 | 2005 | DEVELOP A REPAIR/REPLACE POLICY | $1,002 | $9,712 | Implemented |
OK0717 # 06 Y:2005 | 06 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,658 | $461 | Not Implemented |
OR0491 # 01 Y:2005 | 01 | 2005 | REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS | $22,340 | $0 | Not Implemented |
OR0491 # 02 Y:2005 | 02 | 2005 | MODIFY MATERIAL APPLICATION METHODS | $17,000 | $7,200 | Not Implemented |
OR0491 # 03 Y:2005 | 03 | 2005 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $14,000 | $7,200 | Not Implemented |
OR0491 # 04 Y:2005 | 04 | 2005 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $1,180 | $1,000 | Not Implemented |
OR0491 # 05 Y:2005 | 05 | 2005 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $730 | $1,300 | Not Implemented |
OR0491 # 06 Y:2005 | 06 | 2005 | INSTALL OCCUPANCY SENSORS | $2,440 | $1,900 | Not Implemented |