Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
9,942
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0559 # 09 Y:1998 | 09 | 1998 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,288 | $0 | Implemented |
UD0558 # 01 Y:1998 | 01 | 1998 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $18,790 | $8,000 | Implemented |
UD0558 # 02 Y:1998 | 02 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,343 | $45,360 | Implemented |
UD0558 # 03 Y:1998 | 03 | 1998 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $7,068 | $7,600 | Not Implemented |
UD0558 # 04 Y:1998 | 04 | 1998 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $1,453 | $8,000 | Implemented |
UD0558 # 05 Y:1998 | 05 | 1998 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $1,200 | $0 | Implemented |
UD0557 # 01 Y:1998 | 01 | 1998 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $42,942 | $12,000 | Implemented |
UD0557 # 02 Y:1998 | 02 | 1998 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $60,203 | $0 | Implemented |
UD0557 # 03 Y:1998 | 03 | 1998 | RECYCLE CLEANING SOLVENT AND REUSE | $9,078 | $0 | Not Implemented |
UD0557 # 04 Y:1998 | 04 | 1998 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $7,643 | $1,440 | Not Implemented |
UD0557 # 05 Y:1998 | 05 | 1998 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $4,636 | $6,680 | Not Implemented |
UD0557 # 06 Y:1998 | 06 | 1998 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $1,778 | $0 | Not Implemented |
UD0556 # 01 Y:1998 | 01 | 1998 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $189,046 | $0 | Implemented |
UD0556 # 02 Y:1998 | 02 | 1998 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $19,800 | $0 | Implemented |
UD0556 # 03 Y:1998 | 03 | 1998 | ADJUST BURNERS FOR EFFICIENT OPERATION | $8,037 | $200 | Implemented |
UD0556 # 04 Y:1998 | 04 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,225 | $11,147 | Implemented |
UD0556 # 05 Y:1998 | 05 | 1998 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,784 | $0 | Implemented |
UD0556 # 06 Y:1998 | 06 | 1998 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $2,459 | $0 | Implemented |
UD0556 # 07 Y:1998 | 07 | 1998 | OPTIMIZE PLANT POWER FACTOR | $1,680 | $2,250 | Implemented |
UD0556 # 08 Y:1998 | 08 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $532 | $200 | Implemented |
UD0555 # 01 Y:1998 | 01 | 1998 | EXPAND OPERATIONS INTO UNUSED SPACE | $237,283 | $1,313,000 | Implemented |
UD0555 # 02 Y:1998 | 02 | 1998 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $123,160 | $115,000 | Not Implemented |
UD0555 # 03 Y:1998 | 03 | 1998 | RECOVER WASTE HEAT FROM EQUIPMENT | $22,667 | $20,000 | Not Implemented |
UD0555 # 04 Y:1998 | 04 | 1998 | ELIMINATE/REDUCE AN OPERATION | $17,490 | $0 | Implemented |
UD0555 # 05 Y:1998 | 05 | 1998 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $11,454 | $0 | Implemented |