Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,500
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0391 # 01 Y:2009 | 01 | 2009 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $27,893 | $26,000 | Not Implemented |
WV0391 # 02 Y:2009 | 02 | 2009 | USE PHOTOCELL CONTROLS | $11,811 | $6,850 | Not Implemented |
WV0391 # 03 Y:2009 | 03 | 2009 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $11,520 | $800 | Implemented |
WV0391 # 04 Y:2009 | 04 | 2009 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $9,238 | $8,890 | Not Implemented |
WV0391 # 05 Y:2009 | 05 | 2009 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,896 | $8,900 | Not Implemented |
WV0391 # 06 Y:2009 | 06 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,483 | $105 | Implemented |
WV0391 # 07 Y:2009 | 07 | 2009 | INSTALL / REPAIR INSULATION ON STEAM LINES | $3,782 | $8,543 | Not Implemented |
WV0391 # 08 Y:2009 | 08 | 2009 | DEVELOP A REPAIR/REPLACE POLICY | $2,651 | $605 | Implemented |
WV0391 # 09 Y:2009 | 09 | 2009 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $2,609 | $1,000 | Implemented |
WV0391 # 10 Y:2009 | 10 | 2009 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $374 | $300 | Implemented |
NC0386 # 01 Y:2009 | 01 | 2009 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $31,742 | $49,000 | Not Implemented |
NC0386 # 02 Y:2009 | 02 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,160 | $0 | Not Implemented |
NC0386 # 03 Y:2009 | 03 | 2009 | RECOVER WASTE HEAT FROM EQUIPMENT | $9,621 | $3,300 | Not Implemented |
NC0386 # 04 Y:2009 | 04 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,236 | $100 | Not Implemented |
NC0386 # 05 Y:2009 | 05 | 2009 | DEVELOP A REPAIR/REPLACE POLICY | $2,916 | $2,848 | Not Implemented |
NC0386 # 06 Y:2009 | 06 | 2009 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $1,520 | $0 | Not Implemented |
NC0386 # 07 Y:2009 | 07 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,493 | $6,490 | Not Implemented |
NC0386 # 08 Y:2009 | 08 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,405 | $32,776 | Not Implemented |
NC0386 # 09 Y:2009 | 09 | 2009 | INSTALL OCCUPANCY SENSORS | $6,974 | $8,400 | Not Implemented |
WV0384 # 01 Y:2008 | 01 | 2008 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $13,545 | $1,000 | Not Implemented |
WV0384 # 02 Y:2008 | 02 | 2008 | DEVELOP A REPAIR/REPLACE POLICY | $10,724 | $1,094 | Implemented |
WV0384 # 03 Y:2008 | 03 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,084 | $1,070 | Not Implemented |
WV0384 # 04 Y:2008 | 04 | 2008 | INSULATE BARE EQUIPMENT | $2,032 | $577 | Not Implemented |
WV0384 # 05 Y:2008 | 05 | 2008 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,872 | $2,000 | Not Implemented |
WV0384 # 06 Y:2008 | 06 | 2008 | OPTIMIZE PLANT POWER FACTOR | $1,800 | $11,500 | Not Implemented |