Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,756

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UW0054 # 01 Y:2011 01 2011 REPLACE BROKEN WINDOWS AND/OR WINDOW SASH $25,410 $190,516 Not Implemented
UW0054 # 02 Y:2011 02 2011 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $6,537 $50,000 Not Implemented
UW0054 # 03 Y:2011 03 2011 INSTALL OCCUPANCY SENSORS $3,619 $2,700 Not Implemented
UW0053 # 01 Y:2011 01 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $29,663 $160,551 Implemented
UW0053 # 02 Y:2011 02 2011 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $13,673 $11,000 Implemented
UW0053 # 03 Y:2011 03 2011 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $10,936 $1,900 Implemented
UW0053 # 04 Y:2011 04 2011 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $4,830 $21,939 Not Implemented
UW0053 # 05 Y:2011 05 2011 UTILIZE SENSORS CONTROLLING ROOF AND WALL OPENINGS $3,594 $3,150 Not Implemented
UW0052 # 01 Y:2011 01 2011 HEAT TREAT PARTS ONLY TO REQUIRED SPECIFICATIONS OR STANDARDS $43,653 $0 Not Implemented
UW0052 # 02 Y:2011 02 2011 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $26,448 $326,103 Not Implemented
UW0052 # 03 Y:2011 03 2011 TURN OFF EQUIPMENT WHEN NOT IN USE $22,100 $0 Not Implemented
UW0052 # 04 Y:2011 04 2011 USE RADIANT HEATER FOR SPOT HEATING $10,330 $10,000 Not Implemented
UW0051 # 01 Y:2011 01 2011 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $36,217 $80,000 Not Implemented
UW0051 # 02 Y:2011 02 2011 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $16,962 $29,807 Not Implemented
UW0051 # 03 Y:2011 03 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $8,680 $10,004 Implemented
UW0051 # 04 Y:2011 04 2011 CENTRALIZE CONTROL OF EXHAUST FANS TO ENSURE THEIR SHUTDOWN, OR ESTABLISH PROGRAM TO ENSURE MANUAL SHUTDOWN $4,139 $2,295 Implemented
UW0050 # 01 Y:2011 01 2011 PAY BILLS ON TIME TO AVOID LATE FEES $0 $0 Implemented
UW0049 # 02 Y:2011 02 2011 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $9,443 $7,200 Implemented
UW0049 # 03 Y:2011 03 2011 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,756 $1,300 Implemented
UW0049 # 04 Y:2011 04 2011 INSULATE BARE EQUIPMENT $1,029 $1,810 Not Implemented
UW0049 # 01 Y:2011 01 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $16,931 $67,308 Not Implemented
UW0048 # 01 Y:2011 01 2011 IMPROVE COMBUSTION CONTROL CAPABILITY $308,364 $40,543 Not Implemented
UW0048 # 02 Y:2011 02 2011 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $6,203 $2,440 Not Implemented
UW0047 # 01 Y:2011 01 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $12,466 $57,117 Not Implemented
UW0047 # 02 Y:2011 02 2011 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $6,626 $11,606 Not Implemented