Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,063
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
DL0008 # 01 Y:2007 | 01 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $40,014 | $14,000 | Implemented |
DL0008 # 02 Y:2007 | 02 | 2007 | REPLACE BOILER | $33,159 | $102,000 | Not Implemented |
DL0008 # 03 Y:2007 | 03 | 2007 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $31,900 | $0 | Implemented |
DL0008 # 04 Y:2007 | 04 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $20,801 | $175,000 | Implemented |
DL0008 # 05 Y:2007 | 05 | 2007 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $18,000 | $1,000 | Implemented |
DL0008 # 06 Y:2007 | 06 | 2007 | REPLACE BOILER | $12,509 | $27,400 | Not Implemented |
DL0008 # 07 Y:2007 | 07 | 2007 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,978 | $2,105 | Implemented |
DL0008 # 08 Y:2007 | 08 | 2007 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $3,800 | $900 | Implemented |
DL0008 # 09 Y:2007 | 09 | 2007 | USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS | $2,893 | $14,000 | Not Implemented |
DL0008 # 10 Y:2007 | 10 | 2007 | INSTALL OCCUPANCY SENSORS | $754 | $285 | Implemented |
DL0007 # 01 Y:2007 | 01 | 2007 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $2,993 | $2,583 | Not Implemented |
DL0007 # 02 Y:2007 | 02 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,672 | $75 | Implemented |
DL0007 # 03 Y:2007 | 03 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,535 | $140 | Implemented |
DL0007 # 04 Y:2007 | 04 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $892 | $0 | Not Implemented |
DL0007 # 05 Y:2007 | 05 | 2007 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $181 | $34 | Implemented |
DL0007 # 06 Y:2007 | 06 | 2007 | USE DOUBLE OR TRIPLE GLAZED WINDOWS TO MAINTAIN HIGHER RELATIVE HUMIDITY AND TO REDUCE HEAT LOSSES | $209 | $2,634 | Not Implemented |
DL0007 # 07 Y:2007 | 07 | 2007 | REPLACE BOILER | $1,325 | $10,425 | Implemented |
DL0007 # 08 Y:2007 | 08 | 2007 | USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS | $2,561 | $28,000 | Not Implemented |
DL0006 # 01 Y:2007 | 01 | 2007 | ENHANCE SENSITIVITY OF TEMPERATURE CONTROL AND CUTOFF | $3,642 | $0 | Implemented |
DL0006 # 02 Y:2007 | 02 | 2007 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $2,178 | $0 | Not Implemented |
DL0006 # 03 Y:2007 | 03 | 2007 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $6,925 | $995 | Not Implemented |
DL0005 # 01 Y:2007 | 01 | 2007 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $5,373 | $0 | Implemented |
DL0005 # 02 Y:2007 | 02 | 2007 | REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT | $167,986 | $65,000 | Implemented |
DL0005 # 03 Y:2007 | 03 | 2007 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $92,780 | $18,375 | Implemented |
DL0005 # 04 Y:2007 | 04 | 2007 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $6,554 | $1,772 | Implemented |