Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,568
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0573 # 04 Y:2011 | 04 | 2011 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $8,821 | $7,045 | Not Implemented |
OR0573 # 05 Y:2011 | 05 | 2011 | INSTALL / REPAIR INSULATION ON STEAM LINES | $11,543 | $7,806 | Implemented |
OR0573 # 06 Y:2011 | 06 | 2011 | FLASH CONDENSATE TO PRODUCE LOWER PRESSURE STEAM | $71,712 | $65,575 | Not Implemented |
OR0573 # 07 Y:2011 | 07 | 2011 | INSTALL SOFT-START TO ELIMINATE NUISANCE TRIPS | $987 | $4,800 | Not Implemented |
OR0572 # 01 Y:2011 | 01 | 2011 | UPGRADE CONTROLS ON COMPRESSORS | $6,860 | $3,642 | Implemented |
OR0572 # 02 Y:2011 | 02 | 2011 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $1,220 | $2,280 | Not Implemented |
OR0572 # 03 Y:2011 | 03 | 2011 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $770 | $2,280 | Not Implemented |
OR0572 # 04 Y:2011 | 04 | 2011 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,350 | $4,320 | Implemented |
OR0572 # 05 Y:2011 | 05 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,070 | $4,559 | Not Implemented |
OR0572 # 06 Y:2011 | 06 | 2011 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $8,030 | $14,750 | Not Implemented |
OR0572 # 07 Y:2011 | 07 | 2011 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $1,280 | $500 | Implemented |
OR0572 # 08 Y:2011 | 08 | 2011 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $1,310 | $1,170 | Not Implemented |
OR0570 # 01 Y:2011 | 01 | 2011 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $19,863 | $1,120 | Implemented |
OR0570 # 02 Y:2011 | 02 | 2011 | UPGRADE CONTROLS ON COMPRESSORS | $6,640 | $2,250 | Not Implemented |
OR0570 # 03 Y:2011 | 03 | 2011 | UPGRADE CONTROLS ON COMPRESSORS | $21,600 | $12,010 | Not Implemented |
OR0570 # 04 Y:2011 | 04 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $26,900 | $17,900 | Not Implemented |
OR0570 # 05 Y:2011 | 05 | 2011 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $983 | $1,000 | Not Implemented |
OR0570 # 06 Y:2011 | 06 | 2011 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $695 | $750 | Not Implemented |
OR0570 # 07 Y:2011 | 07 | 2011 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $157,400 | $191,000 | Not Implemented |
OR0570 # 08 Y:2011 | 08 | 2011 | MAKE A NEW BY-PRODUCT | $91,432 | $156,000 | Not Implemented |
OR0570 # 09 Y:2011 | 09 | 2011 | REPLACE OLD MACHINE WITH NEW AUTOMATIC MULTI-STATION TOOL | $543,000 | $1,200,000 | Not Implemented |
OR0570 # 10 Y:2011 | 10 | 2011 | INSTALL SKYLIGHTS | $2,930 | $9,050 | Not Implemented |
OR0570 # 11 Y:2011 | 11 | 2011 | OPTIMIZE PLANT POWER FACTOR | $10,100 | $51,900 | Not Implemented |
OR0571 # 01 Y:2011 | 01 | 2011 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $4,717 | $1,120 | Not Implemented |
OR0571 # 02 Y:2011 | 02 | 2011 | UPGRADE CONTROLS ON COMPRESSORS | $13,809 | $52,890 | Implemented |