IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

3,568

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OR0573 # 04 Y:2011 04 2011 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $8,821 $7,045 Not Implemented
OR0573 # 05 Y:2011 05 2011 INSTALL / REPAIR INSULATION ON STEAM LINES $11,543 $7,806 Implemented
OR0573 # 06 Y:2011 06 2011 FLASH CONDENSATE TO PRODUCE LOWER PRESSURE STEAM $71,712 $65,575 Not Implemented
OR0573 # 07 Y:2011 07 2011 INSTALL SOFT-START TO ELIMINATE NUISANCE TRIPS $987 $4,800 Not Implemented
OR0572 # 01 Y:2011 01 2011 UPGRADE CONTROLS ON COMPRESSORS $6,860 $3,642 Implemented
OR0572 # 02 Y:2011 02 2011 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $1,220 $2,280 Not Implemented
OR0572 # 03 Y:2011 03 2011 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $770 $2,280 Not Implemented
OR0572 # 04 Y:2011 04 2011 INSTALL / REPAIR INSULATION ON STEAM LINES $2,350 $4,320 Implemented
OR0572 # 05 Y:2011 05 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,070 $4,559 Not Implemented
OR0572 # 06 Y:2011 06 2011 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT $8,030 $14,750 Not Implemented
OR0572 # 07 Y:2011 07 2011 ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS $1,280 $500 Implemented
OR0572 # 08 Y:2011 08 2011 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $1,310 $1,170 Not Implemented
OR0570 # 01 Y:2011 01 2011 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $19,863 $1,120 Implemented
OR0570 # 02 Y:2011 02 2011 UPGRADE CONTROLS ON COMPRESSORS $6,640 $2,250 Not Implemented
OR0570 # 03 Y:2011 03 2011 UPGRADE CONTROLS ON COMPRESSORS $21,600 $12,010 Not Implemented
OR0570 # 04 Y:2011 04 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $26,900 $17,900 Not Implemented
OR0570 # 05 Y:2011 05 2011 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $983 $1,000 Not Implemented
OR0570 # 06 Y:2011 06 2011 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $695 $750 Not Implemented
OR0570 # 07 Y:2011 07 2011 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $157,400 $191,000 Not Implemented
OR0570 # 08 Y:2011 08 2011 MAKE A NEW BY-PRODUCT $91,432 $156,000 Not Implemented
OR0570 # 09 Y:2011 09 2011 REPLACE OLD MACHINE WITH NEW AUTOMATIC MULTI-STATION TOOL $543,000 $1,200,000 Not Implemented
OR0570 # 10 Y:2011 10 2011 INSTALL SKYLIGHTS $2,930 $9,050 Not Implemented
OR0570 # 11 Y:2011 11 2011 OPTIMIZE PLANT POWER FACTOR $10,100 $51,900 Not Implemented
OR0571 # 01 Y:2011 01 2011 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $4,717 $1,120 Not Implemented
OR0571 # 02 Y:2011 02 2011 UPGRADE CONTROLS ON COMPRESSORS $13,809 $52,890 Implemented