Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,500
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0333 # 08 Y:2006 | 08 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $278 | $100 | Implemented |
NC0333 # 09 Y:2006 | 09 | 2006 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $1,628 | $3,000 | Not Implemented |
NC0333 # 10 Y:2006 | 10 | 2006 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $7,550 | $4,000 | Not Implemented |
NC0329 # 01 Y:2005 | 01 | 2005 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $4,470 | $3,000 | Not Implemented |
NC0329 # 02 Y:2005 | 02 | 2005 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $1,086 | $2,000 | Not Implemented |
NC0329 # 03 Y:2005 | 03 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $400 | $200 | Implemented |
NC0329 # 04 Y:2005 | 04 | 2005 | DEVELOP A REPAIR/REPLACE POLICY | $38 | $28 | Implemented |
NC0329 # 05 Y:2005 | 05 | 2005 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,036 | $1,770 | Not Implemented |
NC0329 # 06 Y:2005 | 06 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $495 | $50 | Not Implemented |
NC0329 # 07 Y:2005 | 07 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $149 | $249 | Implemented |
NC0329 # 08 Y:2005 | 08 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,379 | $2,200 | Implemented |
NC0325 # 06 Y:2005 | 06 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,733 | $7,500 | Not Implemented |
NC0325 # 01 Y:2005 | 01 | 2005 | INCREASE AMOUNT OF CONDENSATE RETURNED | $27,917 | $25,000 | Not Implemented |
NC0325 # 02 Y:2005 | 02 | 2005 | ADJUST BURNERS FOR EFFICIENT OPERATION | $222,508 | $100,000 | Not Implemented |
NC0325 # 03 Y:2005 | 03 | 2005 | INSTALL / REPAIR INSULATION ON STEAM LINES | $9,902 | $18,198 | Not Implemented |
NC0325 # 04 Y:2005 | 04 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $423 | $1,006 | Not Implemented |
NC0325 # 05 Y:2005 | 05 | 2005 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,395 | $2,000 | Not Implemented |
NC0322 # 01 Y:2005 | 01 | 2005 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $139,400 | $9,500 | Implemented |
NC0322 # 02 Y:2005 | 02 | 2005 | ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL | $8,353 | $2,650 | Implemented |
NC0322 # 03 Y:2005 | 03 | 2005 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $74,009 | $100,000 | Not Implemented |
NC0322 # 04 Y:2005 | 04 | 2005 | DEVELOP A REPAIR/REPLACE POLICY | $573 | $0 | Implemented |
NC0322 # 05 Y:2005 | 05 | 2005 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $2,592 | $821 | Implemented |
NC0322 # 06 Y:2005 | 06 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $462 | $100 | Implemented |
NC0322 # 07 Y:2005 | 07 | 2005 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $723 | $298 | Implemented |
NC0322 # 08 Y:2005 | 08 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $217 | $2,000 | Implemented |