Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,756
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UW0005 # 03 Y:2007 | 03 | 2007 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $3,246 | $1,162 | Implemented |
UW0005 # 04 Y:2007 | 04 | 2007 | MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT | $8,530 | $1,852 | Not Implemented |
UW0005 # 05 Y:2007 | 05 | 2007 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $9,388 | $2,619 | Implemented |
UW0005 # 06 Y:2007 | 06 | 2007 | OPTIMIZE PLANT POWER FACTOR | $6,971 | $17,098 | Not Implemented |
UW0005 # 07 Y:2007 | 07 | 2007 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,766 | $432 | Implemented |
UW0005 # 08 Y:2007 | 08 | 2007 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,795 | $398 | Implemented |
UW0005 # 09 Y:2007 | 09 | 2007 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $354 | $650 | Not Implemented |
UW0003 # 01 Y:2007 | 01 | 2007 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $7,385 | $50,000 | Not Implemented |
UW0003 # 02 Y:2007 | 02 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $929 | $2,100 | Implemented |
UW0003 # 03 Y:2007 | 03 | 2007 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $5,723 | $20,750 | Not Implemented |
UW0003 # 04 Y:2007 | 04 | 2007 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $1,551 | $7,020 | Implemented |
UW0003 # 05 Y:2007 | 05 | 2007 | INSTALL OCCUPANCY SENSORS | $905 | $1,200 | Implemented |
UW0004 # 01 Y:2007 | 01 | 2007 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $13,962 | $8,762 | Implemented |
UW0004 # 02 Y:2007 | 02 | 2007 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $7,182 | $25,800 | Implemented |
UW0004 # 03 Y:2007 | 03 | 2007 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,351 | $5,595 | Not Implemented |
UW0004 # 04 Y:2007 | 04 | 2007 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,362 | $968 | Not Implemented |
UW0002 # 01 Y:2007 | 01 | 2007 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $21,263 | $85,000 | Not Implemented |
UW0002 # 02 Y:2007 | 02 | 2007 | OPTIMIZE PLANT POWER FACTOR | $10,893 | $16,323 | Not Implemented |
UW0002 # 03 Y:2007 | 03 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $8,000 | $9,385 | Implemented |
UW0002 # 04 Y:2007 | 04 | 2007 | INSULATE BARE EQUIPMENT | $5,998 | $2,692 | Implemented |
UW0002 # 05 Y:2007 | 05 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $700 | $252 | Implemented |
UW0002 # 06 Y:2007 | 06 | 2007 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $906 | $653 | Not Implemented |
UW0002 # 07 Y:2007 | 07 | 2007 | INSTALL OCCUPANCY SENSORS | $153 | $200 | Implemented |
UW0001 # 01 Y:2007 | 01 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,324 | $10,082 | Implemented |
UW0001 # 02 Y:2007 | 02 | 2007 | OPTIMIZE PLANT POWER FACTOR | $7,373 | $12,013 | Not Implemented |