IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

9,571

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AM0809 # 02 Y:2020 02 2020 OPTIMIZE PLANT POWER FACTOR $39,500 $80,400 Not Implemented
AM0809 # 03 Y:2020 03 2020 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $17,340 $60,200 Implemented
AM0809 # 04 Y:2020 04 2020 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $9,060 $13,360 Not Implemented
AM0809 # 05 Y:2020 05 2020 PAY UTILITY BILLS ON TIME $3,380 $0 Implemented
AM0809 # 06 Y:2020 06 2020 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $847 $2,360 Implemented
AM0809 # 07 Y:2020 07 2020 INSTALL OCCUPANCY SENSORS $737 $474 Not Implemented
AM0809 # 08 Y:2020 08 2020 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $620 $34 Implemented
AM0809 # 09 Y:2020 09 2020 INSTALL SPECTRAL REFLECTORS / DELAMP $856 $1,020 Implemented
AM0808 # 01 Y:2020 01 2020 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS $89,600 $199,000 Not Implemented
AM0808 # 02 Y:2020 02 2020 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM $10,942 $4,570 Implemented
AM0808 # 03 Y:2020 03 2020 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,862 $4,075 Implemented
AM0808 # 04 Y:2020 04 2020 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $100 $192 Implemented
OK1028 # 01 Y:2020 01 2020 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $5,729 $1,500 Not Implemented
OK1028 # 02 Y:2020 02 2020 USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER $2,193 $3,750 Not Implemented
OK1028 # 03 Y:2020 03 2020 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,990 $3,313 Not Implemented
OK1028 # 04 Y:2020 04 2020 INSULATE BARE EQUIPMENT $53 $111 Not Implemented
OK1028 # 05 Y:2020 05 2020 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $2,802 $8,260 Not Implemented
OK1028 # 06 Y:2020 06 2020 TURN OFF EQUIPMENT WHEN NOT IN USE $258 $616 Not Implemented
TR0027 # 01 Y:2020 01 2020 USE OPTIMUM THICKNESS INSULATION $5,150 $2,324 Implemented
TR0027 # 02 Y:2020 02 2020 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,123 $1,562 Implemented
TR0027 # 03 Y:2020 03 2020 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,856 $4,480 Implemented
TR0027 # 04 Y:2020 04 2020 INSTALL OCCUPANCY SENSORS $44 $60 Implemented
AM0806 # 01 Y:2020 01 2020 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $49,500 $85,000 Not Implemented
AM0806 # 02 Y:2020 02 2020 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $9,025 $24,685 Not Implemented
AM0806 # 03 Y:2020 03 2020 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $8,300 $10,600 Implemented