Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,043
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WM0029 # 05 Y:2013 | 05 | 2013 | TURN OFF EQUIPMENT WHEN NOT IN USE | $9,925 | $4,915 | Implemented |
WM0029 # 06 Y:2013 | 06 | 2013 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $27,541 | $70,000 | Not Implemented |
WM0029 # 07 Y:2013 | 07 | 2013 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $797 | $2,276 | Not Implemented |
WM0029 # 08 Y:2013 | 08 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $149 | $520 | Not Implemented |
WM0029 # 09 Y:2013 | 09 | 2013 | REDUCE FLUID FLOW RATES | $434 | $2,085 | Not Implemented |
WM0029 # 10 Y:2013 | 10 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,633 | $644 | Implemented |
UD0889 # 01 Y:2013 | 01 | 2013 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,100 | $0 | Implemented |
UD0889 # 02 Y:2013 | 02 | 2013 | DEVELOP A REPAIR/REPLACE POLICY | $654 | $460 | Implemented |
UD0889 # 03 Y:2013 | 03 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,448 | $1,000 | Not Implemented |
UD0889 # 04 Y:2013 | 04 | 2013 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $3,551 | $3,500 | Not Implemented |
UD0889 # 05 Y:2013 | 05 | 2013 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,355 | $2,000 | Not Implemented |
UD0889 # 06 Y:2013 | 06 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,219 | $7,254 | Not Implemented |
UD0889 # 07 Y:2013 | 07 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,401 | $9,000 | Not Implemented |
UD0889 # 08 Y:2013 | 08 | 2013 | INSTALL OCCUPANCY SENSORS | $1,290 | $1,400 | Not Implemented |
UK1314 # 01 Y:2013 | 01 | 2013 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $12,434 | $44,000 | Implemented |
UK1314 # 02 Y:2013 | 02 | 2013 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $7,512 | $28,560 | Implemented |
UK1314 # 03 Y:2013 | 03 | 2013 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,739 | $4,500 | Implemented |
UK1314 # 04 Y:2013 | 04 | 2013 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $5,453 | $15,000 | Implemented |
UK1314 # 05 Y:2013 | 05 | 2013 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $4,066 | $0 | Implemented |
UK1314 # 06 Y:2013 | 06 | 2013 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $2,594 | $0 | Implemented |
UK1314 # 07 Y:2013 | 07 | 2013 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,662 | $650 | Implemented |
UK1314 # 08 Y:2013 | 08 | 2013 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $798 | $700 | Implemented |
UK1314 # 09 Y:2013 | 09 | 2013 | USE PHOTOCELL CONTROLS | $328 | $592 | Implemented |
UK1314 # 10 Y:2013 | 10 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $690 | $690 | Implemented |
OR0617 # 01 Y:2013 | 01 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $20,239 | $20,000 | Implemented |