Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,703
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0635 # 04 Y:2014 | 04 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $14,844 | $15,843 | Not Implemented |
OR0635 # 05 Y:2014 | 05 | 2014 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $23,961 | $9,068 | Not Implemented |
OR0635 # 06 Y:2014 | 06 | 2014 | INSTALL SPECTRAL REFLECTORS / DELAMP | $181,002 | $170,561 | Not Implemented |
OR0635 # 07 Y:2014 | 07 | 2014 | UPGRADE CONTROLS ON COMPRESSORS | $40,819 | $43,800 | Not Implemented |
OK0889 # 01 Y:2014 | 01 | 2014 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $15,746 | $14,500 | Not Implemented |
OK0889 # 02 Y:2014 | 02 | 2014 | SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS | $4,415 | $7,547 | Not Implemented |
OK0889 # 03 Y:2014 | 03 | 2014 | INSTALL TIMERS AND/OR THERMOSTATS | $10,189 | $4,650 | Implemented |
OK0889 # 04 Y:2014 | 04 | 2014 | REPLACE HIGH RESISTANCE DUCTS, PIPES, AND FITTINGS | $4,444 | $6,994 | Not Implemented |
OK0889 # 05 Y:2014 | 05 | 2014 | INSTALL OCCUPANCY SENSORS | $1,519 | $5,372 | Not Implemented |
OK0889 # 06 Y:2014 | 06 | 2014 | INSTALL OCCUPANCY SENSORS | $200 | $696 | Not Implemented |
OK0889 # 07 Y:2014 | 07 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,946 | $320 | Not Implemented |
OK0889 # 08 Y:2014 | 08 | 2014 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $815 | $250 | Not Implemented |
OK0889 # 09 Y:2014 | 09 | 2014 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,124 | $239 | Implemented |
OK0889 # 10 Y:2014 | 10 | 2014 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $2,920 | $10,599 | Implemented |
OK0889 # 11 Y:2014 | 11 | 2014 | OPTIMIZE PLANT POWER FACTOR | $4,264 | $2,925 | Not Implemented |
OR0634 # 01 Y:2014 | 01 | 2014 | UPGRADE CONTROLS ON COMPRESSORS | $102,712 | $87,114 | Not Implemented |
OR0634 # 02 Y:2014 | 02 | 2014 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $6,951 | $0 | Not Implemented |
OR0634 # 03 Y:2014 | 03 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $101,299 | $258,445 | Not Implemented |
OR0634 # 04 Y:2014 | 04 | 2014 | TURN OFF EQUIPMENT WHEN NOT IN USE | $4,747 | $1,502 | Not Implemented |
OR0634 # 05 Y:2014 | 05 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,923 | $1,344 | Not Implemented |
OR0634 # 06 Y:2014 | 06 | 2014 | INSTALL SOFT-START TO ELIMINATE NUISANCE TRIPS | $22,225 | $0 | Not Implemented |
LE0384 # 01 Y:2014 | 01 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,262 | $250 | Not Implemented |
LE0384 # 02 Y:2014 | 02 | 2014 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,272 | $1,481 | Implemented |
LE0384 # 03 Y:2014 | 03 | 2014 | INSTALL OR UPGRADE INSULATION ON HVAC DISTRIBUTION SYSTEMS | $1,284 | $1,010 | Not Implemented |
LE0384 # 04 Y:2014 | 04 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,878 | $2,080 | Not Implemented |