Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,032
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0522 # 02 Y:1999 | 02 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,840 | $1,410 | Not Implemented |
KU0522 # 03 Y:1999 | 03 | 1999 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $470 | $0 | Implemented |
KU0522 # 04 Y:1999 | 04 | 1999 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $250 | $500 | Not Implemented |
KU0522 # 05 Y:1999 | 05 | 1999 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $7,710 | $1,100 | Implemented |
KU0522 # 06 Y:1999 | 06 | 1999 | USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES | $2,600 | $4,500 | Implemented |
KU0521 # 01 Y:1999 | 01 | 1999 | USE RADIANT HEATER FOR SPOT HEATING | $3,190 | $8,580 | Not Implemented |
KU0521 # 02 Y:1999 | 02 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $640 | $500 | Implemented |
KU0521 # 03 Y:1999 | 03 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $210 | $270 | Implemented |
KU0521 # 04 Y:1999 | 04 | 1999 | USE SYNTHETIC LUBRICANT | $230 | $640 | Implemented |
KU0521 # 05 Y:1999 | 05 | 1999 | AUTOMATE FINISHING PROCESS | $68,610 | $109,420 | Implemented |
KU0520 # 01 Y:1999 | 01 | 1999 | OPTIMIZE PLANT POWER FACTOR | $5,880 | $4,000 | Not Implemented |
KU0520 # 02 Y:1999 | 02 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $690 | $1,080 | Not Implemented |
KU0520 # 03 Y:1999 | 03 | 1999 | RECOVER WASTE HEAT FROM EQUIPMENT | $410 | $670 | Not Implemented |
KU0520 # 04 Y:1999 | 04 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $250 | $250 | Implemented |
KU0520 # 05 Y:1999 | 05 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $210 | $350 | Implemented |
KU0520 # 06 Y:1999 | 06 | 1999 | TREAT AND REUSE EQUIPMENT CLEANING SOLUTIONS | $3,440 | $3,630 | Implemented |
KU0520 # 07 Y:1999 | 07 | 1999 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $6,720 | $8,000 | Implemented |
KU0520 # 08 Y:1999 | 08 | 1999 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $4,320 | $9,500 | Not Implemented |
KU0519 # 01 Y:1999 | 01 | 1999 | USE IMMERSION HEATING IN TANKS, MELTING POTS, ETC | $8,170 | $11,490 | Not Implemented |
KU0519 # 02 Y:1999 | 02 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,440 | $860 | Implemented |
KU0519 # 03 Y:1999 | 03 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,840 | $350 | Implemented |
KU0519 # 04 Y:1999 | 04 | 1999 | INSULATE BARE EQUIPMENT | $1,140 | $680 | Not Implemented |
KU0519 # 05 Y:1999 | 05 | 1999 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $1,490 | $5,000 | Implemented |
KU0519 # 06 Y:1999 | 06 | 1999 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $270 | $160 | Implemented |
KU0519 # 07 Y:1999 | 07 | 1999 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $84,340 | $24,800 | Implemented |