Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,872
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0229 # 12 Y:1998 | 12 | 1998 | MINIMIZE WATER USAGE | $945 | $400 | Not Implemented |
AS0229 # 13 Y:1998 | 13 | 1998 | USE ULTRASONIC CLEANING | $79,533 | $315,000 | Not Implemented |
AS0229 # 14 Y:1998 | 14 | 1998 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $6,780 | $3,756 | Not Implemented |
NC0145 # 01 Y:1998 | 01 | 1998 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $5,611 | $25,000 | Not Implemented |
NC0145 # 02 Y:1998 | 02 | 1998 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $33,755 | $125,000 | Not Implemented |
NC0145 # 03 Y:1998 | 03 | 1998 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $434 | $25 | Not Implemented |
NC0145 # 04 Y:1998 | 04 | 1998 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $3,308 | $200 | Not Implemented |
NC0145 # 05 Y:1998 | 05 | 1998 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $22,875 | $100 | Implemented |
NC0145 # 06 Y:1998 | 06 | 1998 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $1,125 | $150 | Implemented |
NC0145 # 07 Y:1998 | 07 | 1998 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $9,088 | $1,200 | Not Implemented |
NC0145 # 08 Y:1998 | 08 | 1998 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $111,500 | $405,000 | Not Implemented |
NV0115 # 01 Y:1998 | 01 | 1998 | OPTIMIZE PLANT POWER FACTOR | $1,772 | $2,333 | Implemented |
NV0115 # 02 Y:1998 | 02 | 1998 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,392 | $1,226 | Not Implemented |
NV0115 # 03 Y:1998 | 03 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,937 | $10,398 | Implemented |
NV0115 # 04 Y:1998 | 04 | 1998 | AUTOMATE FINISHING PROCESS | $68,996 | $19,100 | Implemented |
NV0115 # 05 Y:1998 | 05 | 1998 | INSTALL AUTOMATIC PACKING EQUIPMENT | $358,805 | $198,720 | Not Implemented |
NV0115 # 06 Y:1998 | 06 | 1998 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $2,067 | $0 | Not Implemented |
WV0154 # 01 Y:1998 | 01 | 1998 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $1,075 | $2,580 | Not Implemented |
WV0154 # 02 Y:1998 | 02 | 1998 | INSULATE BARE EQUIPMENT | $16,667 | $9,432 | Not Implemented |
WV0154 # 03 Y:1998 | 03 | 1998 | INSULATE BARE EQUIPMENT | $4,282 | $5,130 | Not Implemented |
WV0154 # 04 Y:1998 | 04 | 1998 | INSTALL / REPAIR INSULATION ON STEAM LINES | $322 | $482 | Not Implemented |
WV0154 # 05 Y:1998 | 05 | 1998 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $162 | $550 | Not Implemented |
WV0154 # 06 Y:1998 | 06 | 1998 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $142 | $220 | Not Implemented |
WV0154 # 07 Y:1998 | 07 | 1998 | RECOVER AND REUSE COOLING WATER | $670 | $1,525 | Not Implemented |
WV0154 # 08 Y:1998 | 08 | 1998 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $1,940 | $550 | Not Implemented |