Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,573
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IP0083 # 08 Y:2017 | 08 | 2017 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $23,581 | $23,044 | Implemented |
IP0083 # 09 Y:2017 | 09 | 2017 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $2,902 | $3,417 | Implemented |
IP0083 # 10 Y:2017 | 10 | 2017 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $3,250 | $5,000 | Not Implemented |
IP0083 # 11 Y:2017 | 11 | 2017 | OPTIMIZE PLANT POWER FACTOR | $8,640 | $34,900 | Not Implemented |
IP0082 # 01 Y:2017 | 01 | 2017 | TURN OFF EQUIPMENT WHEN NOT IN USE | $86 | $0 | Implemented |
IP0082 # 02 Y:2017 | 02 | 2017 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $866 | $0 | Implemented |
IP0082 # 03 Y:2017 | 03 | 2017 | PAY BILLS ON TIME TO AVOID LATE FEES | $828 | $0 | Implemented |
IP0082 # 04 Y:2017 | 04 | 2017 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $1,933 | $3 | Not Implemented |
IP0082 # 05 Y:2017 | 05 | 2017 | TURN OFF EQUIPMENT WHEN NOT IN USE | $24,829 | $2,670 | Implemented |
IP0082 # 06 Y:2017 | 06 | 2017 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $7,541 | $1,698 | Not Implemented |
IP0082 # 07 Y:2017 | 07 | 2017 | INSTALL OCCUPANCY SENSORS | $3,769 | $3,724 | Implemented |
IP0082 # 08 Y:2017 | 08 | 2017 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $31,824 | $38,940 | Not Implemented |
IP0082 # 09 Y:2017 | 09 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,194 | $19,486 | Implemented |
IP0082 # 10 Y:2017 | 10 | 2017 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $134 | $270 | Implemented |
IP0082 # 11 Y:2017 | 11 | 2017 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,464 | $9,078 | Not Implemented |
IP0082 # 12 Y:2017 | 12 | 2017 | OPTIMIZE PLANT POWER FACTOR | $7,316 | $21,686 | Implemented |
IP0082 # 13 Y:2017 | 13 | 2017 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $169 | $627 | Not Implemented |
IP0081 # 01 Y:2017 | 01 | 2017 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $1,110 | $0 | Implemented |
IP0081 # 02 Y:2017 | 02 | 2017 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $1,216 | $0 | Implemented |
IP0081 # 03 Y:2017 | 03 | 2017 | TURN OFF EQUIPMENT WHEN NOT IN USE | $72 | $0 | Implemented |
IP0081 # 04 Y:2017 | 04 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,798 | $35 | Implemented |
IP0081 # 05 Y:2017 | 05 | 2017 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,865 | $390 | Implemented |
IP0081 # 06 Y:2017 | 06 | 2017 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $25 | $17 | Not Implemented |
IP0081 # 07 Y:2017 | 07 | 2017 | ENHANCE SENSITIVITY OF TEMPERATURE CONTROL AND CUTOFF | $1,643 | $1,949 | Not Implemented |
IP0081 # 08 Y:2017 | 08 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $832 | $1,358 | Implemented |