Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,193
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0382 # 07 Y:2011 | 07 | 2011 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $9,797 | $31,000 | Not Implemented |
UM0383 # 01 Y:2011 | 01 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,263 | $23,909 | Not Implemented |
UM0383 # 02 Y:2011 | 02 | 2011 | OPTIMIZE PLANT POWER FACTOR | $9,728 | $5,670 | Not Implemented |
UM0383 # 03 Y:2011 | 03 | 2011 | UPGRADE CONTROLS ON COMPRESSORS | $3,151 | $7,125 | Not Implemented |
UM0383 # 04 Y:2011 | 04 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,089 | $1,291 | Not Implemented |
UM0383 # 05 Y:2011 | 05 | 2011 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,601 | $7,500 | Not Implemented |
UM0383 # 06 Y:2011 | 06 | 2011 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $3,466 | $4,400 | Not Implemented |
UM0383 # 07 Y:2011 | 07 | 2011 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,452 | $7,236 | Not Implemented |
UM0383 # 08 Y:2011 | 08 | 2011 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,035 | $1,207 | Not Implemented |
UM0383 # 09 Y:2011 | 09 | 2011 | TREAT AND REUSE RINSE WATERS | $60,914 | $25,231 | Not Implemented |
UM0383 # 10 Y:2011 | 10 | 2011 | HEAT WATER WITH EXHAUST HEAT | $101,682 | $74,000 | Not Implemented |
UM0386 # 01 Y:2011 | 01 | 2011 | INSTALL OCCUPANCY SENSORS | $3,851 | $2,100 | Not Implemented |
UM0386 # 02 Y:2011 | 02 | 2011 | UPGRADE CONTROLS ON COMPRESSORS | $2,043 | $3,615 | Implemented |
UM0386 # 03 Y:2011 | 03 | 2011 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,167 | $1,000 | Implemented |
UM0386 # 04 Y:2011 | 04 | 2011 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $2,885 | $18,495 | Not Implemented |
UM0386 # 05 Y:2011 | 05 | 2011 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $2,336 | $2,471 | Implemented |
UM0386 # 06 Y:2011 | 06 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,285 | $1,000 | Not Implemented |
UM0386 # 07 Y:2011 | 07 | 2011 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $982 | $10 | Not Implemented |
UM0386 # 08 Y:2011 | 08 | 2011 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $16,332 | $92,500 | Not Implemented |
UM0381 # 01 Y:2011 | 01 | 2011 | SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS | $17,794 | $4,850 | Not Implemented |
UM0381 # 02 Y:2011 | 02 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,985 | $5,032 | Implemented |
UM0381 # 03 Y:2011 | 03 | 2011 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $2,946 | $200 | Not Implemented |
UM0381 # 04 Y:2011 | 04 | 2011 | INSTALL OCCUPANCY SENSORS | $119 | $600 | Not Implemented |
UM0381 # 05 Y:2011 | 05 | 2011 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $82 | $10 | Implemented |
UM0381 # 06 Y:2011 | 06 | 2011 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $5,186 | $1,200 | Not Implemented |