IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

4,193

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UM0382 # 07 Y:2011 07 2011 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $9,797 $31,000 Not Implemented
UM0383 # 01 Y:2011 01 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $10,263 $23,909 Not Implemented
UM0383 # 02 Y:2011 02 2011 OPTIMIZE PLANT POWER FACTOR $9,728 $5,670 Not Implemented
UM0383 # 03 Y:2011 03 2011 UPGRADE CONTROLS ON COMPRESSORS $3,151 $7,125 Not Implemented
UM0383 # 04 Y:2011 04 2011 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $2,089 $1,291 Not Implemented
UM0383 # 05 Y:2011 05 2011 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,601 $7,500 Not Implemented
UM0383 # 06 Y:2011 06 2011 PREHEAT COMBUSTION AIR WITH WASTE HEAT $3,466 $4,400 Not Implemented
UM0383 # 07 Y:2011 07 2011 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $3,452 $7,236 Not Implemented
UM0383 # 08 Y:2011 08 2011 INSTALL / REPAIR INSULATION ON STEAM LINES $1,035 $1,207 Not Implemented
UM0383 # 09 Y:2011 09 2011 TREAT AND REUSE RINSE WATERS $60,914 $25,231 Not Implemented
UM0383 # 10 Y:2011 10 2011 HEAT WATER WITH EXHAUST HEAT $101,682 $74,000 Not Implemented
UM0386 # 01 Y:2011 01 2011 INSTALL OCCUPANCY SENSORS $3,851 $2,100 Not Implemented
UM0386 # 02 Y:2011 02 2011 UPGRADE CONTROLS ON COMPRESSORS $2,043 $3,615 Implemented
UM0386 # 03 Y:2011 03 2011 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,167 $1,000 Implemented
UM0386 # 04 Y:2011 04 2011 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS $2,885 $18,495 Not Implemented
UM0386 # 05 Y:2011 05 2011 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $2,336 $2,471 Implemented
UM0386 # 06 Y:2011 06 2011 RECOVER WASTE HEAT FROM EQUIPMENT $2,285 $1,000 Not Implemented
UM0386 # 07 Y:2011 07 2011 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $982 $10 Not Implemented
UM0386 # 08 Y:2011 08 2011 USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR $16,332 $92,500 Not Implemented
UM0381 # 01 Y:2011 01 2011 SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS $17,794 $4,850 Not Implemented
UM0381 # 02 Y:2011 02 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,985 $5,032 Implemented
UM0381 # 03 Y:2011 03 2011 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $2,946 $200 Not Implemented
UM0381 # 04 Y:2011 04 2011 INSTALL OCCUPANCY SENSORS $119 $600 Not Implemented
UM0381 # 05 Y:2011 05 2011 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $82 $10 Implemented
UM0381 # 06 Y:2011 06 2011 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $5,186 $1,200 Not Implemented