Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,314
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0367 # 07 Y:2004 | 07 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $339 | $460 | Not Implemented |
AS0366 # 01 Y:2004 | 01 | 2004 | ADD ADDITIONAL PRODUCTION SHIFT | $66,315 | $18,116 | Not Implemented |
AS0366 # 02 Y:2004 | 02 | 2004 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $11,700 | $18,000 | Not Implemented |
AS0366 # 03 Y:2004 | 03 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,140 | $60 | Implemented |
AS0366 # 04 Y:2004 | 04 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $6,660 | $7,180 | Not Implemented |
AS0366 # 05 Y:2004 | 05 | 2004 | INSTALL AN UNINTERUPTABLE POWER SUPPLY | $1,275 | $573 | Implemented |
AS0366 # 06 Y:2004 | 06 | 2004 | USE SOLAR HEAT TO HEAT WATER | $468 | $1,730 | Not Implemented |
AS0366 # 07 Y:2004 | 07 | 2004 | CONVERT LIQUID HEATERS FROM UNDERFIRING TO IMMERSION OR SUBMERSION HEATING | $468 | $1,150 | Not Implemented |
AS0366 # 08 Y:2004 | 08 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $353 | $1,640 | Implemented |
AS0365 # 01 Y:2003 | 01 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $790 | $1,643 | Implemented |
AS0365 # 02 Y:2003 | 02 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $290 | $1,535 | Implemented |
AS0365 # 03 Y:2003 | 03 | 2003 | INSTALL OCCUPANCY SENSORS | $140 | $450 | Not Implemented |
AS0365 # 04 Y:2003 | 04 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,328 | $60 | Implemented |
AS0365 # 05 Y:2003 | 05 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $183 | $30 | Not Implemented |
AS0365 # 06 Y:2003 | 06 | 2003 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $274 | $350 | Implemented |
AS0365 # 07 Y:2003 | 07 | 2003 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $88,723 | $78,120 | Not Implemented |
AS0365 # 08 Y:2003 | 08 | 2003 | RECOVER AND REUSE WASTE MATERIAL | $2,432 | $1,059 | n/a |
AS0364 # 01 Y:2003 | 01 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,347 | $7,928 | Not Implemented |
AS0364 # 02 Y:2003 | 02 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $221 | $524 | Not Implemented |
AS0364 # 03 Y:2003 | 03 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $990 | $150 | Not Implemented |
AS0364 # 04 Y:2003 | 04 | 2003 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $9,291 | $31,527 | Not Implemented |
AS0364 # 05 Y:2003 | 05 | 2003 | REDUCE VENTILATION AIR | $285 | $10 | Not Implemented |
AS0362 # 01 Y:2003 | 01 | 2003 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $577 | $0 | Implemented |
AS0362 # 02 Y:2003 | 02 | 2003 | INSTALL OCCUPANCY SENSORS | $141 | $450 | Not Implemented |
AS0362 # 03 Y:2003 | 03 | 2003 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $922 | $4,350 | Implemented |