Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,640
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LM0021 # 02 Y:2001 | 02 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $40,680 | $48,707 | Implemented |
LM0021 # 03 Y:2001 | 03 | 2001 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $2,649 | $6,000 | Implemented |
LM0021 # 04 Y:2001 | 04 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $29,054 | $400 | Implemented |
LM0021 # 05 Y:2001 | 05 | 2001 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,216 | $228 | Not Implemented |
LM0021 # 06 Y:2001 | 06 | 2001 | SUBSTITUTE COMPRESSED AIR COOLING WITH WATER OR AIR COOLING | $12,450 | $250 | Not Implemented |
LM0021 # 07 Y:2001 | 07 | 2001 | $203,861 | $40,400 | Not Implemented | |
WV0224 # 01 Y:2001 | 01 | 2001 | INCREASE AMOUNT OF CONDENSATE RETURNED | $34,989 | $13,233 | Implemented |
WV0224 # 02 Y:2001 | 02 | 2001 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $6,320 | $5,782 | Not Implemented |
WV0224 # 03 Y:2001 | 03 | 2001 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $5,209 | $1,000 | Not Implemented |
WV0224 # 04 Y:2001 | 04 | 2001 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $3,489 | $2,436 | Implemented |
WV0224 # 05 Y:2001 | 05 | 2001 | INSULATE BARE EQUIPMENT | $1,215 | $583 | Implemented |
WV0224 # 06 Y:2001 | 06 | 2001 | INSULATE BARE EQUIPMENT | $1,103 | $120 | Implemented |
WV0224 # 07 Y:2001 | 07 | 2001 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $13,668 | $2,160 | Implemented |
WV0224 # 08 Y:2001 | 08 | 2001 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $13,361 | $2,160 | Implemented |
WV0224 # 09 Y:2001 | 09 | 2001 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $8,176 | $31,000 | Not Implemented |
WV0224 # 10 Y:2001 | 10 | 2001 | RECYCLE WHITE WATER | $4,614 | $1,767 | Not Implemented |
WV0224 # 11 Y:2001 | 11 | 2001 | RECOVER AND REUSE COOLING WATER | $25,740 | $89,000 | Implemented |
WV0224 # 12 Y:2001 | 12 | 2001 | $20,000 | $14,000 | Not Implemented | |
WV0224 # 13 Y:2001 | 13 | 2001 | $100,800 | $19,200 | Not Implemented | |
OK0623 # 01 Y:2001 | 01 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,052 | $6,513 | Implemented |
OK0623 # 02 Y:2001 | 02 | 2001 | USE OPTIMUM THICKNESS INSULATION | $8,776 | $550 | Implemented |
OK0623 # 03 Y:2001 | 03 | 2001 | INSTALL SET-BACK TIMERS | $6,800 | $1,035 | Not Implemented |
OK0623 # 04 Y:2001 | 04 | 2001 | REPAIR AND ELIMINATE STEAM LEAKS | $1,256 | $200 | Implemented |
OK0623 # 05 Y:2001 | 05 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $614 | $245 | Not Implemented |
OK0623 # 06 Y:2001 | 06 | 2001 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $8,620 | $21,240 | Implemented |