Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,708
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0248 # 10 Y:2002 | 10 | 2002 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $8,295 | $0 | Implemented |
WV0248 # 11 Y:2002 | 11 | 2002 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $233 | $34 | Implemented |
WV0248 # 12 Y:2002 | 12 | 2002 | CLEAR AND RENT EXISTING SPACE | $4,000 | $670 | Implemented |
SD0303 # 01 Y:2002 | 01 | 2002 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $17,018 | $30,684 | Not Implemented |
SD0303 # 02 Y:2002 | 02 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,991 | $1,642 | Not Implemented |
SD0303 # 03 Y:2002 | 03 | 2002 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $10,435 | $19,000 | Not Implemented |
SD0303 # 04 Y:2002 | 04 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,336 | $6,324 | Not Implemented |
SD0303 # 05 Y:2002 | 05 | 2002 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $3,133 | $500 | Implemented |
SD0303 # 06 Y:2002 | 06 | 2002 | INSTALL OCCUPANCY SENSORS | $1,457 | $1,800 | Not Implemented |
SD0303 # 07 Y:2002 | 07 | 2002 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $3,620 | $6,000 | Not Implemented |
MS0212 # 01 Y:2002 | 01 | 2002 | INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) | $1,698 | $1,707 | Not Implemented |
MS0212 # 02 Y:2002 | 02 | 2002 | USE SYNTHETIC LUBRICANT | $1,158 | $760 | Not Implemented |
MS0212 # 03 Y:2002 | 03 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $982 | $477 | Implemented |
MS0212 # 04 Y:2002 | 04 | 2002 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $29,000 | $79,245 | Implemented |
NC0243 # 01 Y:2002 | 01 | 2002 | INSULATE BARE EQUIPMENT | $1,453 | $3,876 | Not Implemented |
NC0243 # 02 Y:2002 | 02 | 2002 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $3,063 | $1,500 | Not Implemented |
NC0243 # 03 Y:2002 | 03 | 2002 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $236 | $50 | Implemented |
NC0243 # 04 Y:2002 | 04 | 2002 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $1,543 | $6,300 | Implemented |
NC0243 # 05 Y:2002 | 05 | 2002 | REPAIR AND ELIMINATE STEAM LEAKS | $4,291 | $2,500 | Implemented |
NC0243 # 06 Y:2002 | 06 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $200 | $125 | Not Implemented |
NC0243 # 07 Y:2002 | 07 | 2002 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $682 | $351 | Not Implemented |
NC0243 # 08 Y:2002 | 08 | 2002 | DEVELOP A REPAIR/REPLACE POLICY | $820 | $1,753 | Implemented |
UM0221 # 01 Y:2002 | 01 | 2002 | LIMIT AND CONTROL SECONDARY COMBUSTION AIR IN FURNACE | $40,400 | $4,000 | Implemented |
UM0221 # 02 Y:2002 | 02 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $20,486 | $7,425 | Implemented |
UM0221 # 03 Y:2002 | 03 | 2002 | RECOVER WASTE HEAT FROM EQUIPMENT | $8,720 | $2,000 | Not Implemented |