Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

162,450

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0279 # 12 Y:1989 12 1989 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $14,887 $7,200 Not Implemented
OK0280 # 01 Y:1989 01 1989 MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION $3,000 $4,600 Implemented
OK0280 # 02 Y:1989 02 1989 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $782 $231 Implemented
OK0280 # 03 Y:1989 03 1989 INSTALL / REPAIR INSULATION ON STEAM LINES $6,280 $893 Implemented
OK0280 # 04 Y:1989 04 1989 OPTIMIZE PLANT POWER FACTOR $1,270 $3,200 Not Implemented
OK0280 # 05 Y:1989 05 1989 INSTALL SET-BACK TIMERS $272 $0 Implemented
OK0280 # 06 Y:1989 06 1989 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $499 $602 Implemented
UD0288 # 01 Y:1989 01 1989 USE SMALL NUMBER OF HIGH OUTPUT UNITS INSTEAD OF MANY SMALL INEFFICIENT UNITS $441,279 $200,000 Not Implemented
UD0288 # 02 Y:1989 02 1989 REDUCE VENTILATION AIR $30,846 $10,000 Implemented
UD0288 # 03 Y:1989 03 1989 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $23,159 $10,000 Implemented
UD0288 # 04 Y:1989 04 1989 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $31,629 $90,000 Not Implemented
UD0288 # 05 Y:1989 05 1989 LOWER LIGHT FIXTURES IN HIGH CEILING AREAS $803 $0 Implemented
UD0289 # 01 Y:1989 01 1989 INSTALL TIMERS AND/OR THERMOSTATS $3,618 $1,000 Not Implemented
UD0289 # 02 Y:1989 02 1989 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $2,453 $0 Implemented
UD0289 # 03 Y:1989 03 1989 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,150 $4,000 Not Implemented
UD0289 # 04 Y:1989 04 1989 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $791 $1,000 Not Implemented
UD0289 # 05 Y:1989 05 1989 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $356 $75 Implemented
UD0289 # 06 Y:1989 06 1989 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $9,331 $25,000 Not Implemented
UD0289 # 07 Y:1989 07 1989 RECOVER AND REUSE COOLING WATER $5,791 $20,000 Not Implemented
TN0366 # 04 Y:1989 04 1989 KEEP LAMPS AND REFLECTORS CLEAN $10,766 $33,188 Not Implemented
TN0366 # 05 Y:1989 05 1989 INCREASE AMOUNT OF CONDENSATE RETURNED $1,712 $4,156 Implemented
TN0366 # 06 Y:1989 06 1989 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $8,977 $330 Implemented
TN0366 # 07 Y:1989 07 1989 RECOVER WASTE HEAT FROM EQUIPMENT $959 $1,960 Not Implemented
TN0366 # 08 Y:1989 08 1989 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $556 $0 Implemented
TN0366 # 09 Y:1989 09 1989 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $4,404 $4,000 Implemented