Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
158,920
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0046 # 01 Y:1985 | 01 | 1985 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $738 | $1,650 | Not Implemented |
MA0046 # 02 Y:1985 | 02 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $530 | $74 | Implemented |
MA0046 # 03 Y:1985 | 03 | 1985 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $3,418 | $168 | Not Implemented |
MA0046 # 04 Y:1985 | 04 | 1985 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $924 | $1,350 | Not Implemented |
MA0046 # 05 Y:1985 | 05 | 1985 | OPTIMIZE PLANT POWER FACTOR | $776 | $1,875 | Not Implemented |
MA0047 # 01 Y:1985 | 01 | 1985 | UPGRADE OBSOLETE EQUIPMENT | $11,304 | $0 | Implemented |
MA0047 # 02 Y:1985 | 02 | 1985 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,175 | $821 | Implemented |
MA0047 # 03 Y:1985 | 03 | 1985 | HEAT WATER WITH EXHAUST HEAT | $1,144 | $2,804 | Implemented |
MA0047 # 04 Y:1985 | 04 | 1985 | REPAIR OR REPLACE STEAM TRAPS | $16,278 | $715 | Implemented |
MA0047 # 05 Y:1985 | 05 | 1985 | INSTALL TIMERS AND/OR THERMOSTATS | $3,640 | $2,000 | Implemented |
MA0043 # 01 Y:1985 | 01 | 1985 | HEAT WATER WITH EXHAUST HEAT | $1,549 | $1,473 | Not Implemented |
MA0043 # 02 Y:1985 | 02 | 1985 | UPGRADE OBSOLETE EQUIPMENT | $2,907 | $0 | Not Implemented |
MA0043 # 03 Y:1985 | 03 | 1985 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $68 | $60 | Not Implemented |
MA0043 # 04 Y:1985 | 04 | 1985 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $332 | $100 | Not Implemented |
MA0043 # 05 Y:1985 | 05 | 1985 | OPTIMIZE PLANT POWER FACTOR | $993 | $2,500 | Not Implemented |
MA0043 # 06 Y:1985 | 06 | 1985 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,590 | $500 | Implemented |
MA0043 # 07 Y:1985 | 07 | 1985 | USE COOLING AIR WHICH COOLS HOT WORK PIECES FOR SPACE HEATING | $1,989 | $1,700 | Not Implemented |
MA0044 # 01 Y:1985 | 01 | 1985 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $760 | $1,390 | Implemented |
MA0044 # 02 Y:1985 | 02 | 1985 | INSTALL TIMERS AND/OR THERMOSTATS | $1,253 | $600 | Implemented |
LT0028 # 01 Y:1985 | 01 | 1985 | INSULATE BARE EQUIPMENT | $3,836 | $1,550 | Not Implemented |
LT0028 # 02 Y:1985 | 02 | 1985 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,990 | $0 | Implemented |
LT0028 # 03 Y:1985 | 03 | 1985 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $1,165 | $0 | Implemented |
LT0028 # 04 Y:1985 | 04 | 1985 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,628 | $120 | Implemented |
LT0028 # 05 Y:1985 | 05 | 1985 | INSTALL TIMERS AND/OR THERMOSTATS | $116 | $150 | Implemented |
LT0028 # 06 Y:1985 | 06 | 1985 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $148 | $59 | Not Implemented |