Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
162,429
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0220 # 02 Y:1987 | 02 | 1987 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $6,871 | $10,000 | Not Implemented |
UD0220 # 03 Y:1987 | 03 | 1987 | MINIMIZE WATER USAGE | $1,991 | $300 | Implemented |
UD0220 # 04 Y:1987 | 04 | 1987 | HEAT WATER WITH EXHAUST HEAT | $2,530 | $2,000 | Not Implemented |
UD0221 # 01 Y:1987 | 01 | 1987 | USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS | $3,915 | $20,000 | Not Implemented |
UD0221 # 02 Y:1987 | 02 | 1987 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $16,515 | $0 | Implemented |
UD0221 # 03 Y:1987 | 03 | 1987 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,218 | $0 | Implemented |
UD0221 # 04 Y:1987 | 04 | 1987 | MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION | $7,322 | $10,000 | Implemented |
UD0221 # 05 Y:1987 | 05 | 1987 | INSTALL TIMERS AND/OR THERMOSTATS | $7,926 | $9,000 | Implemented |
UD0221 # 06 Y:1987 | 06 | 1987 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $2,822 | $2,070 | Implemented |
UD0222 # 01 Y:1987 | 01 | 1987 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $50,976 | $0 | Implemented |
UD0222 # 02 Y:1987 | 02 | 1987 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $12,018 | $6,000 | Not Implemented |
UD0222 # 03 Y:1987 | 03 | 1987 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $28,028 | $25,000 | Implemented |
UD0222 # 04 Y:1987 | 04 | 1987 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $26,250 | $27,000 | Implemented |
TN0296 # 01 Y:1986 | 01 | 1986 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $7,812 | $25,175 | Not Implemented |
TN0296 # 02 Y:1986 | 02 | 1986 | INSTALL TIMERS AND/OR THERMOSTATS | $6,477 | $2,580 | Implemented |
TN0296 # 03 Y:1986 | 03 | 1986 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $2,236 | $0 | Implemented |
TN0296 # 04 Y:1986 | 04 | 1986 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $3,601 | $0 | Implemented |
TN0296 # 05 Y:1986 | 05 | 1986 | INSULATE BARE EQUIPMENT | $853 | $596 | Not Implemented |
TN0296 # 06 Y:1986 | 06 | 1986 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,336 | $260 | Implemented |
TN0278 # 01 Y:1986 | 01 | 1986 | INSTALL TIMERS AND/OR THERMOSTATS | $6,537 | $2,810 | Not Implemented |
TN0278 # 02 Y:1986 | 02 | 1986 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $4,026 | $4,844 | Not Implemented |
TN0278 # 03 Y:1986 | 03 | 1986 | USE MINIMUM STEAM OPERATING PRESSURE | $929 | $420 | Not Implemented |
TN0278 # 04 Y:1986 | 04 | 1986 | INSULATE BARE EQUIPMENT | $590 | $682 | Not Implemented |
TN0278 # 05 Y:1986 | 05 | 1986 | USE MINIMUM STEAM OPERATING PRESSURE | $382 | $0 | Not Implemented |
TN0278 # 06 Y:1986 | 06 | 1986 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $348 | $68 | Not Implemented |