Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,289
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0426 # 05 Y:2011 | 05 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $302 | $25 | Implemented |
NC0426 # 06 Y:2011 | 06 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $98 | $100 | Implemented |
NC0426 # 07 Y:2011 | 07 | 2011 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $5,569 | $21,550 | Not Implemented |
NC0427 # 01 Y:2011 | 01 | 2011 | BURN A LESS EXPENSIVE GRADE OF FUEL | $155,882 | $10,000 | Implemented |
NC0427 # 02 Y:2011 | 02 | 2011 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $209,278 | $1,200 | Not Implemented |
NC0427 # 03 Y:2011 | 03 | 2011 | KEEP BOILER TUBES CLEAN | $164,666 | $20,000 | Implemented |
NC0427 # 04 Y:2011 | 04 | 2011 | KEEP BOILER TUBES CLEAN | $104,205 | $18,000 | Implemented |
NC0427 # 05 Y:2011 | 05 | 2011 | LOWER OPERATING PRESSURE OF CONDENSER (STEAM) | $178,345 | $50,000 | Implemented |
NC0427 # 06 Y:2011 | 06 | 2011 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $10,000 | $200 | Implemented |
NC0427 # 07 Y:2011 | 07 | 2011 | INSULATE FEEDWATER TANK | $3,200 | $1,200 | Implemented |
NC0427 # 08 Y:2011 | 08 | 2011 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $3,000 | $600 | Implemented |
NC0427 # 09 Y:2011 | 09 | 2011 | REPAIR AND ELIMINATE STEAM LEAKS | $106,205 | $1,200 | Implemented |
NC0427 # 10 Y:2011 | 10 | 2011 | REPAIR OR REPLACE STEAM TRAPS | $5,500 | $150 | Not Implemented |
NC0427 # 11 Y:2011 | 11 | 2011 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $2,500 | $1,050 | Not Implemented |
NC0427 # 12 Y:2011 | 12 | 2011 | INCREASE AMOUNT OF CONDENSATE RETURNED | $126,880 | $500,000 | Not Implemented |
NC0425 # 01 Y:2011 | 01 | 2011 | TURN OFF EQUIPMENT WHEN NOT IN USE | $14,162 | $5,000 | Implemented |
NC0425 # 02 Y:2011 | 02 | 2011 | DEVELOP A REPAIR/REPLACE POLICY | $2,202 | $3,750 | Not Implemented |
NC0425 # 03 Y:2011 | 03 | 2011 | USE RADIANT HEATER FOR SPOT HEATING | $3,993 | $10,500 | Not Implemented |
NC0425 # 04 Y:2011 | 04 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $347 | $100 | Implemented |
NC0425 # 05 Y:2011 | 05 | 2011 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $420 | $25 | Not Implemented |
NC0425 # 06 Y:2011 | 06 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,542 | $25 | Not Implemented |
NC0425 # 07 Y:2011 | 07 | 2011 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $491 | $700 | Not Implemented |
NC0425 # 08 Y:2011 | 08 | 2011 | INSTALL OCCUPANCY SENSORS | $630 | $980 | Implemented |
NC0425 # 09 Y:2011 | 09 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,465 | $3,975 | Implemented |
NC0425 # 10 Y:2011 | 10 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $20,987 | $71,380 | Implemented |