Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,666
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UA0037 # 11 Y:2009 | 11 | 2009 | USE RADIANT HEATER FOR SPOT HEATING | $7,231 | $16,448 | Not Implemented |
UA0037 # 12 Y:2009 | 12 | 2009 | INSTALL TIMERS AND/OR THERMOSTATS | $16,135 | $1,700 | Implemented |
GT0865 # 01 Y:2009 | 01 | 2009 | USE DRYING OVEN (BATCH TYPE) ON ALTERNATE DAYS OR OTHER OPTIMUM SCHEDULE TO RUN EQUIPMENT WITH FULL LOADS | $23,450 | $0 | Not Implemented |
GT0865 # 02 Y:2009 | 02 | 2009 | REDUCE FLUID FLOW RATES | $3,226 | $1,220 | Not Implemented |
GT0865 # 03 Y:2009 | 03 | 2009 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $5,697 | $1,100 | Not Implemented |
GT0865 # 04 Y:2009 | 04 | 2009 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,003 | $1,920 | Not Implemented |
GT0865 # 05 Y:2009 | 05 | 2009 | USE RADIANT HEATER FOR SPOT HEATING | $5,208 | $8,000 | Not Implemented |
GT0865 # 06 Y:2009 | 06 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $40,450 | $84,450 | Implemented |
GT0865 # 07 Y:2009 | 07 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,256 | $15,290 | Implemented |
GT0865 # 08 Y:2009 | 08 | 2009 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $69,163 | $135,000 | Not Implemented |
IC0156 # 01 Y:2009 | 01 | 2009 | ADD AREA LIGHTING SWITCHES | $10,860 | $8,096 | Implemented |
IC0156 # 02 Y:2009 | 02 | 2009 | INSTALL OCCUPANCY SENSORS | $4,252 | $4,247 | Implemented |
IC0156 # 03 Y:2009 | 03 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,116 | $1,649 | Implemented |
IC0156 # 04 Y:2009 | 04 | 2009 | DISCONNECT BALLASTS | $2,089 | $2,200 | Implemented |
IC0156 # 05 Y:2009 | 05 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,483 | $29,250 | Implemented |
IC0156 # 06 Y:2009 | 06 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,309 | $5,917 | Implemented |
IC0156 # 07 Y:2009 | 07 | 2009 | DEVELOP A REPAIR/REPLACE POLICY | $4,792 | $15,044 | Implemented |
IC0156 # 08 Y:2009 | 08 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,513 | $1,610 | Not Implemented |
IC0156 # 09 Y:2009 | 09 | 2009 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $8,278 | $7,995 | Not Implemented |
IC0156 # 10 Y:2009 | 10 | 2009 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $934 | $0 | Implemented |
IC0156 # 11 Y:2009 | 11 | 2009 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,559 | $2,887 | Implemented |
IC0156 # 12 Y:2009 | 12 | 2009 | INSTALL TIMERS AND/OR THERMOSTATS | $1,299 | $0 | Implemented |
AM0558 # 01 Y:2009 | 01 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $59,900 | $3,000 | Implemented |
AM0558 # 02 Y:2009 | 02 | 2009 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $6,000 | $37,000 | Not Implemented |
AM0558 # 03 Y:2009 | 03 | 2009 | TURN OFF EQUIPMENT WHEN NOT IN USE | $5,055 | $0 | Implemented |