Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,872
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0556 # 04 Y:1998 | 04 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,225 | $11,147 | Implemented |
UD0556 # 05 Y:1998 | 05 | 1998 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,784 | $0 | Implemented |
UD0556 # 06 Y:1998 | 06 | 1998 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $2,459 | $0 | Implemented |
UD0556 # 07 Y:1998 | 07 | 1998 | OPTIMIZE PLANT POWER FACTOR | $1,680 | $2,250 | Implemented |
UD0556 # 08 Y:1998 | 08 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $532 | $200 | Implemented |
NC0146 # 01 Y:1998 | 01 | 1998 | COVER OPEN TANKS | $488 | $600 | Implemented |
NC0146 # 02 Y:1998 | 02 | 1998 | INSULATE BARE EQUIPMENT | $920 | $800 | Implemented |
NC0146 # 03 Y:1998 | 03 | 1998 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $409 | $1,480 | Implemented |
NC0146 # 04 Y:1998 | 04 | 1998 | RECOVER WASTE HEAT FROM EQUIPMENT | $178 | $200 | Implemented |
NC0146 # 05 Y:1998 | 05 | 1998 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $13,890 | $1,500 | Implemented |
NC0146 # 06 Y:1998 | 06 | 1998 | REDUCE SOLUTION DRAG-OUT TO PREVENT SOLUTION LOSS | $2,431 | $0 | Implemented |
OK0552 # 01 Y:1998 | 01 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,497 | $26,747 | Implemented |
OK0552 # 02 Y:1998 | 02 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $48,699 | $25,866 | Not Implemented |
OK0552 # 03 Y:1998 | 03 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $819 | $700 | Implemented |
OK0552 # 04 Y:1998 | 04 | 1998 | INSTALL OCCUPANCY SENSORS | $873 | $651 | Implemented |
OK0552 # 05 Y:1998 | 05 | 1998 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $142 | $54 | Implemented |
OK0552 # 06 Y:1998 | 06 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $581 | $375 | Implemented |
OK0552 # 07 Y:1998 | 07 | 1998 | REDUCE EXCESSIVE BOILER BLOWDOWN | $1,324 | $5,000 | Implemented |
OK0552 # 08 Y:1998 | 08 | 1998 | INSULATE BARE EQUIPMENT | $193 | $209 | Implemented |
OK0552 # 09 Y:1998 | 09 | 1998 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $1,072 | $7,000 | Not Implemented |
OK0552 # 10 Y:1998 | 10 | 1998 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,474 | $6,000 | Not Implemented |
OK0552 # 11 Y:1998 | 11 | 1998 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $3,909 | $15,000 | Not Implemented |
OK0552 # 12 Y:1998 | 12 | 1998 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $1,291 | $3,000 | Not Implemented |
CO0422 # 01 Y:1998 | 01 | 1998 | CHECK FOR ACCURACY OF UTILITY / POWER METERS | $5,830 | $0 | Implemented |
CO0422 # 02 Y:1998 | 02 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $404 | $1,292 | Not Implemented |