Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,640
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MS0188 # 05 Y:2001 | 05 | 2001 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $8,358 | $6,500 | Not Implemented |
WV0220 # 01 Y:2001 | 01 | 2001 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,623 | $3,010 | Implemented |
WV0220 # 02 Y:2001 | 02 | 2001 | USE PHOTOCELL CONTROLS | $432 | $300 | Implemented |
WV0220 # 03 Y:2001 | 03 | 2001 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,633 | $540 | Implemented |
WV0220 # 04 Y:2001 | 04 | 2001 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $804 | $54 | Implemented |
WV0220 # 05 Y:2001 | 05 | 2001 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $241 | $36 | Implemented |
WV0220 # 06 Y:2001 | 06 | 2001 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $1,872 | $1,457 | Not Implemented |
WV0220 # 07 Y:2001 | 07 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,626 | $190 | Implemented |
WV0220 # 08 Y:2001 | 08 | 2001 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,369 | $708 | Not Implemented |
WV0220 # 09 Y:2001 | 09 | 2001 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $1,742 | $3,132 | Not Implemented |
WV0220 # 10 Y:2001 | 10 | 2001 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $4,164 | $1,080 | Implemented |
WV0220 # 11 Y:2001 | 11 | 2001 | BURN WASTE OIL FOR HEAT | $3,635 | $4,700 | Not Implemented |
WV0220 # 12 Y:2001 | 12 | 2001 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $5,188 | $7,000 | Not Implemented |
WV0220 # 13 Y:2001 | 13 | 2001 | ADD ADDITIONAL PRODUCTION SHIFT | $110,160 | $63,182 | Not Implemented |
GT0716 # 01 Y:2001 | 01 | 2001 | REDESIGN PROCESS | $807,905 | $500,000 | n/a |
GT0716 # 02 Y:2001 | 02 | 2001 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $12,800 | $0 | n/a |
GT0716 # 03 Y:2001 | 03 | 2001 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $201 | $450 | n/a |
GT0716 # 04 Y:2001 | 04 | 2001 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,000 | $2,000 | n/a |
GT0716 # 05 Y:2001 | 05 | 2001 | FILTER AND REUSE HYDRAULIC OIL | $9,825 | $0 | n/a |
GT0716 # 06 Y:2001 | 06 | 2001 | FILTER AND REUSE HYDRAULIC OIL | $18,150 | $5,900 | n/a |
WI0403 # 01 Y:2001 | 01 | 2001 | INSTALL AUTOMATIC PART STORAGE / RETREVAL SYSTEM | $82,500 | $120,000 | Not Implemented |
WI0403 # 02 Y:2001 | 02 | 2001 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $20,523 | $0 | Implemented |
WI0403 # 03 Y:2001 | 03 | 2001 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $7,035 | $9,500 | Not Implemented |
WI0403 # 04 Y:2001 | 04 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,569 | $16,804 | Not Implemented |
WI0403 # 05 Y:2001 | 05 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $188 | $630 | Implemented |