Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,533
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IC0105 # 04 Y:2005 | 04 | 2005 | INSTALL DE-AERATOR IN PLACE OF CONDENSATE TANK | $12,910 | $900 | Not Implemented |
IC0105 # 05 Y:2005 | 05 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,728 | $42,000 | Not Implemented |
IC0105 # 06 Y:2005 | 06 | 2005 | INSTALL OCCUPANCY SENSORS | $94 | $713 | Not Implemented |
IC0105 # 07 Y:2005 | 07 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $255 | $714 | Not Implemented |
IC0105 # 08 Y:2005 | 08 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,344 | $13,017 | Not Implemented |
SD0368 # 01 Y:2005 | 01 | 2005 | REPAIR AND ELIMINATE STEAM LEAKS | $85,079 | $99,260 | Not Implemented |
SD0368 # 02 Y:2005 | 02 | 2005 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $82,308 | $130,000 | Not Implemented |
SD0368 # 03 Y:2005 | 03 | 2005 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $49,689 | $30,500 | Not Implemented |
SD0368 # 04 Y:2005 | 04 | 2005 | REPAIR OR REPLACE STEAM TRAPS | $41,386 | $11,940 | Not Implemented |
SD0368 # 05 Y:2005 | 05 | 2005 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $39,379 | $59,781 | Not Implemented |
SD0368 # 06 Y:2005 | 06 | 2005 | INSTALL / REPAIR INSULATION ON STEAM LINES | $5,259 | $4,056 | Not Implemented |
SD0368 # 07 Y:2005 | 07 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,660 | $13,282 | Not Implemented |
SD0368 # 08 Y:2005 | 08 | 2005 | SELL / OFFER BY-PRODUCT AS ANIMAL FEED | $539,275 | $68,000 | Not Implemented |
SD0368 # 09 Y:2005 | 09 | 2005 | MAKE A NEW BY-PRODUCT | $194,263 | $172,000 | Not Implemented |
SD0368 # 10 Y:2005 | 10 | 2005 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $15,102 | $20,000 | Not Implemented |
SD0368 # 11 Y:2005 | 11 | 2005 | INSTALL EQUIPMENT TO MOVE PRODUCT | $80,484 | $5,965 | Not Implemented |
SD0369 # 01 Y:2005 | 01 | 2005 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $169,717 | $252,000 | Not Implemented |
SD0369 # 02 Y:2005 | 02 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $17,291 | $0 | Implemented |
SD0369 # 03 Y:2005 | 03 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $6,639 | $648 | Not Implemented |
SD0369 # 04 Y:2005 | 04 | 2005 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,877 | $12,575 | Not Implemented |
SD0369 # 05 Y:2005 | 05 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,896 | $10,102 | Implemented |
SD0369 # 06 Y:2005 | 06 | 2005 | INSTALL OCCUPANCY SENSORS | $395 | $80 | Implemented |
SD0369 # 07 Y:2005 | 07 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $285 | $161 | Implemented |
SD0369 # 08 Y:2005 | 08 | 2005 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $12,744 | $17,000 | Not Implemented |
MI0111 # 01 Y:2005 | 01 | 2005 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $13,372 | $200 | Not Implemented |