IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

5,872

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OD0116 # 03 Y:1998 03 1998 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $921 $800 Implemented
OD0116 # 04 Y:1998 04 1998 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $95 $91 Implemented
OD0116 # 05 Y:1998 05 1998 USE SYNTHETIC LUBRICANT $255 $255 Implemented
SF0145 # 01 Y:1998 01 1998 REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS $1,575 $0 Implemented
SF0145 # 02 Y:1998 02 1998 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $6,958 $0 Implemented
SF0145 # 03 Y:1998 03 1998 REPAIR AND ELIMINATE STEAM LEAKS $2,548 $600 Implemented
SF0145 # 04 Y:1998 04 1998 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $382 $150 Implemented
SF0145 # 05 Y:1998 05 1998 INSTALL OCCUPANCY SENSORS $2,965 $4,440 Not Implemented
SF0145 # 06 Y:1998 06 1998 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,334 $3,981 Implemented
SF0145 # 07 Y:1998 07 1998 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $3,553 $11,064 Not Implemented
SF0145 # 08 Y:1998 08 1998 USE PHOTOCELL CONTROLS $7,051 $27,750 Not Implemented
SF0145 # 09 Y:1998 09 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,405 $21,900 Not Implemented
SF0145 # 10 Y:1998 10 1998 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE $7,480 $550 Implemented
SF0145 # 11 Y:1998 11 1998 METER WASTE WATER $91,785 $180,000 Not Implemented
SF0145 # 12 Y:1998 12 1998 PURCHASE APPROPRIATELY SIZED MATERIAL $39,680 $15,000 Implemented
SF0145 # 13 Y:1998 13 1998 AUTOMATE FINISHING PROCESS $2,816 $5,000 Implemented
UD0555 # 01 Y:1998 01 1998 EXPAND OPERATIONS INTO UNUSED SPACE $237,283 $1,313,000 Implemented
UD0555 # 02 Y:1998 02 1998 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES $123,160 $115,000 Not Implemented
UD0555 # 03 Y:1998 03 1998 RECOVER WASTE HEAT FROM EQUIPMENT $22,667 $20,000 Not Implemented
UD0555 # 04 Y:1998 04 1998 ELIMINATE/REDUCE AN OPERATION $17,490 $0 Implemented
UD0555 # 05 Y:1998 05 1998 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $11,454 $0 Implemented
UD0555 # 06 Y:1998 06 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,882 $17,546 Implemented
AM0330 # 01 Y:1998 01 1998 OPTIMIZE PLANT POWER FACTOR $19,460 $17,210 Not Implemented
AM0330 # 02 Y:1998 02 1998 CHECK FOR ACCURACY OF UTILITY / POWER METERS $4,820 $0 Implemented
AM0330 # 03 Y:1998 03 1998 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $4,560 $100 Implemented