IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,871

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UL0182 # 05 Y:1997 05 1997 INSTALL BACK-UP EQUIPMENT $23,221 $8,900 Not Implemented
UL0183 # 01 Y:1997 01 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,385 $2,200 Implemented
UL0183 # 02 Y:1997 02 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $151 $2,700 Not Implemented
UL0183 # 03 Y:1997 03 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $4,200 $260 Not Implemented
UL0183 # 04 Y:1997 04 1997 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $11,650 $40 Not Implemented
UL0183 # 05 Y:1997 05 1997 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS $40,200 $82,600 Not Implemented
UL0183 # 06 Y:1997 06 1997 CLEAR AND RENT EXISTING SPACE $130,000 $2,400 Implemented
UL0181 # 01 Y:1997 01 1997 UPGRADE OBSOLETE EQUIPMENT $139 $0 Not Implemented
UL0181 # 02 Y:1997 02 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $350 $8,500 Not Implemented
UL0181 # 03 Y:1997 03 1997 INSULATE BARE EQUIPMENT $3,388 $786 Not Implemented
UL0181 # 04 Y:1997 04 1997 INSULATE BARE EQUIPMENT $415 $263 Not Implemented
UL0181 # 05 Y:1997 05 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $476 $3,157 Not Implemented
UL0181 # 06 Y:1997 06 1997 REGENERATE CLEANING SOLVENT ON-SITE AND REUSE $19,550 $56,265 Not Implemented
UL0181 # 07 Y:1997 07 1997 USE ABSORPTION, EXTRACTION TO REMOVE CONTAMINANTS $5,165 $60 Not Implemented
TN0611 # 01 Y:1997 01 1997 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK $201,410 $28,000 Implemented
TN0611 # 02 Y:1997 02 1997 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $34,735 $41,885 Implemented
TN0611 # 03 Y:1997 03 1997 DISTILL CONTAMINATED SOLVENTS FOR REUSE $9,975 $9,596 Not Implemented
TN0611 # 04 Y:1997 04 1997 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $1,330 $3,240 Implemented
TN0611 # 05 Y:1997 05 1997 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $860 $0 Implemented
TN0610 # 01 Y:1997 01 1997 MODIFY CURRENT INCENTIVE PROGRAM $118,000 $10,000 n/a
TN0610 # 02 Y:1997 02 1997 INSTALL EQUIPMENT TO MOVE PRODUCT $56,055 $50,060 n/a
TN0610 # 03 Y:1997 03 1997 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $32,660 $11,800 n/a
TN0610 # 04 Y:1997 04 1997 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $15,220 $3,600 n/a
TN0610 # 05 Y:1997 05 1997 INSTALL SET-BACK TIMERS $7,910 $3,520 n/a
TN0610 # 06 Y:1997 06 1997 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $630 $250 n/a